Título: Enhanced Selectivity and Stability of Ruthenium Purple-Modified Carbon Fiber Microelectrodes for Detection of Hydrogen Peroxide in Brain Tissue
Autor: Ledo, Ana Margarida da Cruz 
Fernandes, Eliana
Brett, Christopher M. A. 
Barbosa, Rui Manuel da Silva Gomes 
Palavras-chave: Carbon fiber microelectrode; ruthenium purple; hydrogen peroxide; brain slices
Data: 15-Mai-2020
Editora: Elsevier B.V.
Projeto: POCI-01-0145-FEDER-028261 
UID/EMS/00285/2020 
UIDB/04539/2020 
Título da revista, periódico, livro ou evento: Sensors and Actuators B: Chemical
Volume: 311
Número: 311
Resumo: Microelectrodes coupled to fast electrochemical techniques are an attractive approach towards real time in vivo monitoring with minimal damage to living tissue. Here, carbon fiber microelectrodes (CFM) were modified by electrodeposition of ruthenium purple (RP) for monitoring of H2O2 concentration dynamics in brain tissue preparations. The RP-modified CFM (CFM-RP) showed catalytic activity for the reduction of H2O2 at -0.1 V vs. Ag/AgCl in aqueous electrolyte at neutral pH and in the presence of physiological concentration of sodium cation (154 mM). The CFM-RP displayed a linear response in the concentration range of 2-500 µM, with a sensitivity of 0.98 ± 0.37 µA cm-2 µM-1 and a limit of detection of 70 ± 40 nM. Coating the CFM-RP with a Nafion® layer greatly extended the operational stability of the RP film to 3 hours in a medium containing a high sodium concentration at physiological pH 7.4. Validation of the CFM-RP-Nafion® sensor suitability for monitoring H2O2 concentration dynamics was achieved by measuring exogenously and locally applied H2O2 in rodent striatal slices. Together, these results support the excellent analytical performance of this new CFM-RP-Nafion® sensor design for sensitive and selective monitoring of H2O2 concentration dynamics in brain tissue.
URI: https://hdl.handle.net/10316/93146
ISSN: 09254005
DOI: 10.1016/j.snb.2020.127899
Direitos: embargoedAccess
Aparece nas coleções:I&D CNC - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Ledo et al _Accepted.pdfAccepted Manuscript1.1 MBAdobe PDFVer/Abrir
Suppl Data.pdfSupplementary Data237.36 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

14
Visto em 1/abr/2024

Citações WEB OF SCIENCETM

12
Visto em 2/abr/2024

Visualizações de página

178
Visto em 16/abr/2024

Downloads

123
Visto em 16/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.