Título: Ion Mobility Studies Mixtures used in gas detectors
Autor: Encarnação, Pedro Manuel Crispim da Costa da 
Orientador: Soares, Filipa Isabel Gouveia de Melo Borges Belo
Cortez, André Filipe Ventura
Palavras-chave: Charge transport and multiplication in gas; Ion sources (positive ions, negative ions); Gaseous detectors; Ionization and excitation processes; Ion mobility.; Transporte de cargas e multiplicação em gases; Fontes de iões (iões positivos, iões negativos); Detetores gasosos; Processos de ionização e excitação; Mobilidade de iões
Data: Jul-2016
Citação: Encarnação, Pedro Manuel Crispim da Costa da / Ion Mobility Studies Mixtures used in gas detectors
Local de edição ou do evento: Coimbra
Resumo: Time Projection Chambers (TPC) allow a three-dimensional reconstruction of a particle trajectory or interaction that uses a sensitive gas as detection medium. This detectors have large volumes, and for an appropriate and improved operation it is essential to understand what is the detector’s behaviour if the gas parameters such as composition, pressure, temperature and type of gas are changed. In the scope of our participation in the RD51 collaboration/CERN, a common project was established with GSI Darmstag (Germany), Uluda˘g University (Turkey) and VECC (India) regarding the study of ion transport properties of relevant gas mixtures for ALICE TPC. With this in mind, we performed experimental ion mobility measurements, K0, for several gases and gas mixtures, namely for pure carbon dioxide, carbon dioxide mixtures (Ar-CO2, Ne-CO2, Ne-CO2-N2 and N2-CO2), pure nitrogen, nitrogen mixtures (Ne-N2), pure trimethylamine (TMA) and xenon-trimethylamine (Xe-TMA) mixtures. The results are presented for total pressures ranging from 4-20 Torr and for reduced electric fields (E=N) generally in the 10-25 Td range (6 to 60 Td in the case of pure gases), at room temperature. The IDC (Ion Drift Chamber) used to conduct the ion mobility studies was initially developed by P. N. B. Neves [4]. The techniques to perform the aforementioned studies are described in this report and make used of a Gaseous ElectronMultiplier (GEM) and a UV flash lamp to produce the ions. Also, a new, more practical and automatic method of analysis was developed in the form of a standalone application during this thesis program, which is also explained in this document. Finally, a redesign of the experimental system in order to improve it is suggested. Keywords:
Descrição: Dissertação de Mestrado em Engenharia Física apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
URI: https://hdl.handle.net/10316/31829
Direitos: openAccess
Aparece nas coleções:UC - Dissertações de Mestrado
FCTUC Física - Teses de Mestrado

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Pedro Manuel Crispim da Costa da Encarnac¸˜ao.pdf13.81 MBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Visualizações de página 50

456
Visto em 16/jul/2024

Downloads

241
Visto em 16/jul/2024

Google ScholarTM

Verificar


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.