Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/26914
Title: Biomimetic sensor based on hemin/carbon nanotubes/chitosan modified microelectrode for nitric oxide measurement in the brain
Authors: Santos, Ricardo M. 
Rodrigues, Marcelo S. 
Laranjinha, João 
Barbosa, Rui M. 
Keywords: Nitric oxide microsensor; Hemin; Carbon nanotubes; Chitosan; In vivo electrochemistry
Issue Date: 15-Jun-2013
Publisher: Elsevier
Citation: SANTOS, Ricardo M. [et al.] - Biomimetic sensor based on hemin/carbon nanotubes/chitosan modified microelectrode for nitric oxide measurement in the brain. "Biosensors and Bioelectronics". ISSN 0956-5663. Vol. 44 (2013) p. 152-159
Serial title, monograph or event: Biosensors and Bioelectronics
Volume: 44
Abstract: A novel biomimetic microsensor for measuring nitric oxide (NO) in the brain in vivo was developed. The sensor consists of hemin and functionalized multi-wall carbon nanotubes covalently attached to chitosan via the carbodiimide crosslinker EDC followed by chitosan electrodeposition on the surface of carbon fiber microelectrodes. Cyclic voltammetry supported direct electron transfer from the FeIII/FeII couple of hemin to the carbon surface at −0.370 V and −0.305 V vs. Ag/AgCl for cathodic and anodic peaks, respectively. Square wave voltammetry revealed a NO reduction peak at −0.762 V vs. Ag/AgCl that increased linearly with NO concentration between 0.25 and 1 μM. The average sensitivity of the microsensors was 1.72 nA/μM and the limit of detection was 25 nM. Oxygen and hydrogen peroxide reduction peaks were observed at −0.269 V and −0.332 V vs. Ag/AgCl, respectively and no response was observed for other relevant interferents, namely ascorbate, nitrite and dopamine. The microsensor was successfully applied to the measurement of exogenously applied NO in the rat brain in vivo.
URI: https://hdl.handle.net/10316/26914
ISSN: 0956-5663
DOI: 10.1016/j.bios.2013.01.015
Rights: openAccess
Appears in Collections:FFUC- Artigos em Revistas Internacionais
I&D CNC - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
Biomimetic Sensor Based on Hemin.pdf619.79 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

63
checked on Nov 9, 2022

WEB OF SCIENCETM
Citations 1

63
checked on May 2, 2023

Page view(s)

373
checked on Apr 16, 2024

Download(s) 50

652
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.