Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/12916
Título: Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Autor: Cardoso, A. J. Marques 
Cruz, S. M. A. 
Fonseca, D. S. B. 
Palavras-chave: Induction motors; Fault diagnosis; Stator winding faults; Insulation failure
Data: Set-1999
Editora: IEEE
Citação: IEEE Transactions on Energy Conversion. 14:3 (1999) 595-598
Resumo: The subject of on-line detection and location of inter-turn short circuits in the stator windings of three-phase induction motors is discussed, and a noninvasive approach, based on the computer-aided monitoring of the stator current Park's vector, is introduced. Experimental results, obtained by using a special fault producing test rig, demonstrate the effectiveness of the proposed technique, for detecting inter-turn stator winding faults in operating three-phase induction machines. On-site tests conducted in a power generation plant, using the diagnostic instrumentation system developed, are also reported
URI: https://hdl.handle.net/10316/12916
ISSN: 0885-8969
DOI: 10.1109/60.790920
Direitos: openAccess
Aparece nas coleções:FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Inter-turn stator winding fault diagnosis.pdf343.68 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

279
Visto em 26/ago/2024

Citações WEB OF SCIENCETM

213
Visto em 2/ago/2024

Visualizações de página 20

834
Visto em 27/ago/2024

Downloads 20

1.144
Visto em 27/ago/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.