Título: Why are tapes better than wires in knotless rotator cuff repairs? An evaluation of force, pressure and contact area in a tendon bone unit mechanical model
Autor: Maia Dias, Carlos
Gonçalves, Sérgio B
Completo, António 
Tognini, Martina
da Silva, Manuel Ribeiro
Mineiro, Jorge
Curate, Francisco 
Ferreira, Frederico
Folgado, João
Palavras-chave: Rotator; Cuff; Tape; Wire; Suture; Force; Pressure; Area
Data: 3-Fev-2021
Editora: Springer Nature
Projeto: UIDB/50022/2020 
Título da revista, periódico, livro ou evento: Journal of Experimental Orthopaedics
Volume: 8
Número: 1
Resumo: Knotless repairs have demonstrated encouraging performance regarding retear rate reduction, but literature aiming at identifying the specific variables responsible for these results is scarce and conflictive. The purpose of this paper was to evaluate the effect of the material (tape or wire suture) and medial tendon passage (single or double passage) on the contact force, pressure and area at the tendon bone interface in order to identify the key factors responsible for this repairs´ success. Methods: A specific knotless transosseous equivalent cuff repair was simulated using 2 tape or suture wire loaded medial anchors and 2 lateral anchors, with controlled lateral suture limb tension. The repair was performed in a previously validated sawbones® mechanical model. Testing analyzed force, pressure and area in a predetermined and constant size “repair box” using a Tekscan® sensor, as well as peak force and pressure, force applied by specific sutures and force variation along the repair box. Results: Tapes generate lower contact force and pressure and double medial passage at the medial tendon is associated with higher contact area. Suture wires generate higher peak force and pressure on the repair and higher mean force in their tendon path and at the medial bearing row. Force values decrease from medial to lateral and from posterior to anterior independently of the material or medial passage. Conclusion: Contrary to most biomechanical literature, suture tape use lowers the pressure and force applied at the tendon bone junction, while higher number of suture passage points medially increases the area of contact. These findings may explain the superior clinical results obtained with the use uf suture tapes because its smaller compressive effect over the tendon may create a better perfusion environment healing while maintaining adequate biomechanical stability.
URI: https://hdl.handle.net/10316/104863
ISSN: 2197-1153
DOI: 10.1186/s40634-020-00321-y
Direitos: openAccess
Aparece nas coleções:FCTUC Ciências da Vida - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Citações WEB OF SCIENCETM

2
Visto em 2/mai/2023

Visualizações de página

50
Visto em 7/mai/2024

Downloads

25
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons