Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/94072
Título: Long-term continuous positive airway pressure treatment ameliorates biological clock disruptions in obstructive sleep apnea
Autor: Gaspar, Laetitia S. 
Hesse, Janina
Yalçin, Müge
Santos, Bárbara
Carvalhas-Almeida, Catarina
Ferreira, Mafalda 
Moita, Joaquim
Relógio, Angela
Cavadas, Cláudia 
Álvaro, Ana Rita 
Palavras-chave: Biological clock; Clock genes; Continuous positive airway pressure (CPAP); Machine learning; Obstructive sleep apnea
Data: Mar-2021
Editora: Elsevier
Projeto: Healthy Aging 2020: CENTRO-01-0145-FEDER-000012 
UIDB/04539/2020 
PD/BD/135497/2018 
Título da revista, periódico, livro ou evento: EBioMedicine
Volume: 65
Resumo: Background Obstructive Sleep Apnea (OSA) is a highly prevalent and underdiagnosed sleep disorder. Recent studies suggest that OSA might disrupt the biological clock, potentially causing or worsening OSA-associated comorbidities. However, the effect of OSA treatment on clock disruption is not fully understood. Methods The impact of OSA and short- (four months) and long-term (two years) OSA treatment, with Continuous Positive Airway Pressure (CPAP), on the biological clock was investigated at four time points within 24 h, in OSA patients relative to controls subjects (no OSA) of the same sex and age group, in a case-control study. Plasma melatonin and cortisol, body temperature and the expression levels and rhythmicity of eleven clock genes in peripheral blood mononuclear cells (PBMCs) were assessed. Additional computational tools were used for a detailed data analysis. Findings OSA impacts on clock outputs and on the expression of several clock genes in PBMCs. Neither short- nor long-term treatment fully reverted OSA-induced alterations in the expression of clock genes. However, long-term treatment was able to re-establish levels of plasma melatonin and cortisol and body temperature. Machine learning methods could discriminate controls from untreated OSA patients. Following long-term treatment, the distinction between controls and patients disappeared, suggesting a closer similarity of the phenotypes. Interpretation OSA alters biological clock-related characteristics that differentially respond to short- and long-term CPAP treatment. Long-term CPAP was more efficient in counteracting OSA impact on the clock, but the obtained results suggest that it is not fully effective. A better understanding of the impact of OSA and OSA treatment on the clock may open new avenues to OSA diagnosis, monitoring and treatment.
URI: https://hdl.handle.net/10316/94072
ISSN: 23523964
DOI: 10.1016/j.ebiom.2021.103248
Direitos: openAccess
Aparece nas coleções:I&D CIBB - Artigos em Revistas Internacionais
IIIUC - Artigos em Revistas Internacionais
FFUC- Artigos em Revistas Internacionais
I&D CNC - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
1-s2.0-S2352396421000414-main.pdf4.57 MBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

17
Visto em 1/abr/2024

Citações WEB OF SCIENCETM

16
Visto em 2/abr/2024

Visualizações de página

177
Visto em 9/abr/2024

Downloads

147
Visto em 9/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons