Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/87759
Título: Thermal transmittance of lightweight steel framed walls: Experimental versus numerical and analytical approaches
Autor: Santos, Paulo
Gonçalves, Margarida
Martins, Cláudio Alexandre de Sousa 
Soares, Nelson 
Costa, José J. 
Palavras-chave: Lightweight steel framing; LSF walls; Thermal transmittance; U-value; Experimental measurements; Numerical simulations; Analytical approach
Data: 2019
Editora: Elsevier
Projeto: POCI-01-0145-FEDER-016750 | PTDC/EMS-ENE/6079/2014 
Título da revista, periódico, livro ou evento: Journal of Building Engineering
Volume: 25
Resumo: Given the great influence of the thermal transmittance of the building envelope on the overall thermal performance and energy efficiency of the building, it is essential to accurately determine the U-value of the main building envelope elements. Due to the great heterogeneity of the thermal conductivity of the elements presented in a lightweight steel-framed (LSF) wall, and to the geometric complexity of some steel framed structures, a reliable estimation of the thermal transmittance of LSF elements is even more challenging. Indeed, thermal bridging originated by steel studs must be considered in the assessment of the thermal transmittance of LSF walls. In this work, the thermal transmittance (U-value) of three LSF walls with different configurations will be investigated based on four different approaches: experimental laboratorial measurements based on the Heat Flow Meter (HFM) method; 3D finite element method (FEM) simulations using ANSYS CFX® software; 2D FEM-based simulations using THERM software; analytical estimations based on the ISO 6946 procedure for building components with inhomogeneous layers. Several verification procedures were performed to ensure the reliability of the results. It was found that a secondary wood stud can mitigate the thermal bridging effect of the steel frame and improve the LSF thermal performance, which is more noticeable when there is no thermal insulation. Furthermore, a good agreement was found between the results of the 2D FEM and the analytical ISO 6946 approaches for the LSF wall with only vertical steel studs.
URI: https://hdl.handle.net/10316/87759
ISSN: 23527102
DOI: 10.1016/j.jobe.2019.100776
Direitos: openAccess
Aparece nas coleções:UC Bibliotecas - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Citações SCOPUSTM   

43
Visto em 19/fev/2024

Citações WEB OF SCIENCETM
5

42
Visto em 2/fev/2024

Visualizações de página

260
Visto em 17/abr/2024

Downloads

754
Visto em 17/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.