Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/4565
Título: A study of breakdown limits in microstrip gas counters with preamplification structures
Autor: Fonte, P. 
Peskov, V. 
Ramsey, B. D. 
Data: 1998
Citação: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 416:1 (1998) 23-31
Resumo: We have studied the charge and breakdown limits of Microstrip Gas Counters (MSGC's) with two different preamplification structures: the Gas Electron Multiplier (GEM) and the Parallel-Plate Avalanche Counter (PPAC). It was found that in both cases the breakdown limit was increased by 1-2 orders of magnitude compared to the bare MSGC and that this was due to the spreading of the primary electron cloud during pre-amplification. This spreading reduces the charge density in the final MSGC avalanche, permitting much higher total gains before streamers form. The real practical gain limitations in these two-stage detectors arose not from sparking, but from a loss of proportionality due to space charge effects.
URI: https://hdl.handle.net/10316/4565
DOI: 10.1016/S0168-9002(98)00649-4
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
filef2237a3c1b17475995c4abf304dea898.pdf227.79 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

22
Visto em 22/abr/2024

Citações WEB OF SCIENCETM

20
Visto em 2/abr/2024

Visualizações de página

315
Visto em 23/abr/2024

Downloads

233
Visto em 23/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.