dc.descriptionDissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbrapt
dc.description.abstractAtualmente, para avaliar o estado funcional de um sistema é possível utilizar técnicas não destrutivas, em alternativa à utilização de técnicas invasivas. A termografia tem-se revelado um poderoso método de inspeção não destrutivo em edifícios, devido à maioria dos defeitos e componentes dos materiais estar associado à temperatura, pelo que a sua medição é essencial para a deteção e caracterização destes. Para um melhor conhecimento da técnica de termografia foi estudado o seu funcionamento, particularmente aspetos teóricos referentes à medição da temperatura e parâmetros que afetam a medição da radiação emitida pelas superfícies. De forma a avaliar a técnica de termografia, implementou-se uma extensa campanha termográfica com o intuito de avaliar as suas potencialidades e limitações na avaliação qualitativa de fachadas. Assim foi possível verificar na prática, os conceitos analisados na teoria, identificar as dificuldades e formas de as superar. Foram escolhidos nove edifícios caracterizados por apresentarem revestimentos distintos e efetuada uma análise qualitativa às suas fachadas. Os dados recolhidos serviram para identificar a influência das diversas condicionantes aquando da aplicação da técnica da termografia in situ. Estas condicionantes são a orientação da fachada, altura do dia, condições meteorológicas, meio circundante e características do próprio edifício.pt
dc.description.abstractCurrently, to assess the functional state of a system can use non-destructive techniques in alternative to the use of invasive techniques. Thermography has proved a powerful method for non-destructive inspection of buildings, because most of the defects of materials and components to be associated with temperature, so that its measurement is essential for the detection and characterization thereof. For a better understanding of the technique of thermography functioning, particularly theoretical aspects related to the measurement of temperature and parameters that affect the measurement of the radiation emitted by the surfaces was studied. In order to evaluate the technique of thermography, implemented an extensive thermography campaign in order to evaluate their strengths and limitations in the qualitative evaluation of facades. Thus it was possible to verify in practice the concepts analyzed in theory, identify the difficulties and ways to overcome them. Nine buildings were chosen with different coatings and performed a qualitative analysis of its facades. The data collected were used to identify the influence of various conditions when applying the technique of thermography in situ. These constraints are the orientation of the facade, time of day, weather conditions, surrounding environment and characteristics of the building itself.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectTermografiapt
dc.subjectFachadas de edifíciospt
dc.titleUso da termografia para caracterizar qualitativamente fachadas de edifíciospt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2014-09-09*
dc.identifier.tid201658917pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia Civilpt
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
uc.controloAutoridadeSim-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.openairetypemasterThesis-
item.languageiso639-1pt-
item.fulltextCom Texto completo-
item.cerifentitytypePublications-
crisitem.advisor.researchunitCentre for Research in Construction Science-
crisitem.advisor.researchunitCentre for Research in Construction Science-
crisitem.advisor.orcid0000-0003-2535-8458-
crisitem.advisor.orcid0000-0003-3418-0030-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Files in This Item:
Show simple item record

Page view(s)

368
checked on Aug 27, 2024

Download(s) 20

1,801
checked on Aug 27, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.