Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/27889
Título: | A new self-assembled layer-by-layer glucose biosensor based on chitosan biopolymer entrapped enzyme with nitrogen doped graphene | Autor: | Barsan, Madalina M. David, Melinda Florescu, Monica Ţugulea, Laura Brett, Christopher M. A. |
Palavras-chave: | Layer-by layer; Quartz crystal microbalance; Nitrogen doped graphene; Enzyme; Chitosan | Data: | Out-2014 | Editora: | Elsevier | Citação: | BARSAN, Madalina M. [et. al] - A new self-assembled layer-by-layer glucose biosensor based on chitosan biopolymer entrapped enzyme with nitrogen doped graphene. "Bioelectrochemistry". ISSN 1567-5394. Vol. 99 (2014) p. 46–52 | Título da revista, periódico, livro ou evento: | Bioelectrochemistry | Volume: | 99 | Resumo: | The layer-by-layer (LbL) technique has been used for the construction of a new enzyme biosensor. Multilayer films containing glucose oxidase, GOx, and nitrogen-doped graphene (NG) dispersed in the biocompatible positively-charged polymer chitosan (chit+(NG + GOx)), together with the negatively charged polymer poly(styrene sulfonate), PSS−, were assembled by alternately immersing a gold electrode substrate in chit+(NG + GOx) and PSS− solutions. Gravimetric monitoring during LbL assembly by an electrochemical quartz microbalance enabled investigation of the adsorption mechanism and deposited mass for each monolayer. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the LbL modified electrodes, in order to establish the contribution of each monolayer to the overall electrochemical properties of the biosensor. The importance of NG in the biosensor architecture was evaluated by undertaking a comparative study without NG in the chit layer. The GOx biosensor's analytical properties were evaluated by fixed potential chronoamperometry and compared with similar reported biosensors. The biosensor operates at a low potential of − 0.2 V vs., Ag/AgCl, exhibiting a high sensitivity of 10.5 μA cm− 2 mM− 1, and a detection limit of 64 μM. This study shows a simple approach in developing new biosensor architectures, combining the advantages of nitrogen-doped graphene with the LbL technique for enzyme immobilization. | URI: | https://hdl.handle.net/10316/27889 | ISSN: | 1567-5394 | DOI: | 10.1016/j.bioelechem.2014.06.004 | Direitos: | openAccess |
Aparece nas coleções: | FCTUC Química - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
A new self-assembled layer-by-layer glucose biosensor.pdf | 253.74 kB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
72
Visto em 14/out/2024
Citações WEB OF SCIENCETM
1
65
Visto em 2/out/2024
Visualizações de página 50
507
Visto em 15/out/2024
Downloads 50
641
Visto em 15/out/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.