Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/12904
Título: Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
Autor: Dias, Teresa H. V. T. 
Stauffer, A. D. 
Conde, C. A. N. 
Data: Fev-1983
Editora: IEEE
Citação: IEEE Transactions on Nuclear Science 30:1 (1983) 389-393
Resumo: An unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data available
URI: https://hdl.handle.net/10316/12904
ISSN: 0018-9499
DOI: 10.1109/TNS.1983.4332296
Direitos: openAccess