Title: Enhancing Polyantimonic-Based Materials’ Moisture Response with Binder Content Tuning
Authors: Mendes, Sofia 
Kurapova, Olga
Faia, Pedro M. 
Keywords: humidity sensing; electrical impedance spectroscopy; polyantimonic-based sensors; PVA; model circuit
Issue Date: 2023
Publisher: MDPI
Project: FCT scholarship UI/BD/152285/2021 
Serial title, monograph or event: Chemosensors
Volume: 11
Issue: 8
Abstract: Humidity sensors are of huge importance in diverse domains. Several types of materials present a moisture-sensing capacity; however, frequently, their electrical response does not display time stability. Due to its high thermal stability, high ionic conductivity, and different conduction mechanism contributing to its overall conductivity, polyantimonic acid (PAA) is seen as a promising material for humidity-sensing devices. In the present work, crystalline PAA was obtained via a simple and safe hydrolysis technique using SbCl3 as a precursor. Bulky sensor samples were produced using different amounts of polyvinyl alcohol (10–20 wt.% PVA) as a binder. The obtained PAA solid sensors were tested at room temperature (RT) in order to evaluate their moisture detection/measuring ability in the relative humidity range 0–100%; the evaluation was carried out with electrical impedance spectroscopy. The sample’s structure and morphology were studied using diverse experimental techniques (porosimetry, scanning electron microscopy, X-ray diffraction analysis, and thermogravimetry analysis, etc.). The sensors’ electrical response was in line with the found structural and morphological features. The slope of the resistance variation with an RH percentage concentration between 1 kW and 1.5 kW was noted for all sensors (showing no changes with time) in the interval between 30 and 100% RH. A good repeatability and reproducibility of the evaluated sensors’ electrical response was observed: the ones that displayed a higher sensitivity were the ones with a high PVA binder content, higher than previously published results for PAA, as well as a very good time stability along the time and low hysteresis.
URI: https://hdl.handle.net/10316/112231
ISSN: 2227-9040
DOI: 10.3390/chemosensors11080423
Rights: openAccess
Appears in Collections:FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais
I&D CEMMPRE - Artigos em Revistas Internacionais

Show full item record

Page view(s)

19
checked on Apr 24, 2024

Download(s)

22
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons