Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/111875
Título: Experimental Assessment and Validation of the Hygrothermal Behaviour of an Innovative Light Steel Frame (LSF) Wall Incorporating a Monitoring System
Autor: Jerónimo, Rui 
Gonçalves, Márcio 
Furtado, Cristina
Rodrigues, Kevin António 
Ferreira, César
Simões, Nuno 
Palavras-chave: light steel frame; hygrothermal performance; innovative profile; monitoring system; U-value determination
Data: 2023
Editora: MDPI
Projeto: UIDB/04625/2020 
SMARTLSF project (POCI-01-0247- FEDER-039955) co-financed by the European Regional Development Fund (FEDER) 
Título da revista, periódico, livro ou evento: Buildings
Volume: 13
Número: 10
Resumo: Currently, the construction sector is witnessing a growing demand for lightweight solutions, which can be justified by the need to adopt high-performance solutions and the fact that the industry is struggling with a shortage of skilled labour. In this sense, this study focuses on a novel and flexible building wall system, constructed using an innovative extensible LSF profile. To enhance its functionality, a monitoring system comprising printed sensors was integrated into the wall. These sensors underwent a thorough verification process. To evaluate the hygrothermal performance of the complete LSF wall solution and validate the novel monitoring system, an extensive ageing test focused on heat/rain, freeze/thaw cycles was conducted on a large-scale wall prototype. Additionally, this research introduces a novel approach by simulating exceptional solar radiation conditions, surpassing the standard cycles outlined in EAD 040083-00-0404, for the first time in this kind of solution. The results cover the measurements taken inside the building system using the incorporated monitoring system. Additionally, supplementary external temperature and heat flow sensors were used to determine the thermal transmittance. Visual and thermography inspections were also carried out. The findings reveal no instances of failures or defects that could potentially impact the hygrothermal behaviour of the system. The hybrid LSF constructive solution leads to more stable temperatures on the inner surface. The presence of direct solar radiation can raise surface temperatures by up to 5 C compared to surfaces not exposed to such radiation, even when a light-coloured surface is used. The monitoring system worked correctly. In conclusion, the innovative profile proved to be resistant to hygrothermal cycles and the monitoring system developed is efficient.
URI: https://hdl.handle.net/10316/111875
ISSN: 2075-5309
DOI: 10.3390/buildings13102509
Direitos: openAccess
Aparece nas coleções:FCTUC Eng.Civil - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Visualizações de página

34
Visto em 17/jul/2024

Downloads

42
Visto em 17/jul/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons