Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/108360
Título: Do we need bone mineral density to estimate osteoporotic fracture risk? A 10-year prospective multicentre validation study
Autor: Marques, Andréa 
Lucas, Raquel
Simões, Eugénia
Verstappen, Suzanne M. M.
Jacobs, Johannes W. G.
Silva, José A. P. da 
Palavras-chave: epidemiology; osteoporosis; outcomes research
Data: 2017
Editora: BMJ Publishing Group
Projeto: unrestricted grants from the Direção Geral da Saúde and Amgen 
Título da revista, periódico, livro ou evento: RMD Open
Volume: 3
Número: 2
Resumo: Objective E valuate the performance of FRAX®, with and without bone mineral densitometry (BMD), in predicting the occurrence of fragility fractures over 10 years. Methods Participants aged ≥40 years at baseline, with a complete set of data and a minimum of 8.5 years of follow-up were identified from three cohorts (n=2626). Ten-year fracture risk at baseline were estimated with FRAX® and assessed by comparison with observed fractures and receiver operating characteristic analysis. Results During a mean (SD) follow-up of 9.12 (1.5) years, 178 participants suffered a major osteoporotic (MOP) fracture and 28 sustained a hip fracture. The predictive performance of FRAX® was superior to that of BMD alone for both MOP and hip fractures. The area under the curve (AUC) of FRAX® without BMD was 0.76 (95% CI 0.72 to 0.79) for MOP fractures and 0.78 (95% CI 0.69 to 0.86) for hip fractures. No significant improvements were found when BMD was added to clinical variables to predict either MOP (0.78, 95% CI 0.74 to 0.82, p=0.25) or hip fractures (0.79, 95% CI 0.69 to 0.89, p=0.72). A UCs for FRAX® (with and without BMD) were greater for men than for women. FRAX®, with and without BMD, tended to underestimate the number of MOP fractures and to overestimate the number of hip fractures in females. In men, the number of observed fractures were within the 95% CI of the number predicted, both with and without BMD. Conclusion FRAX® without BMD provided good fracture prediction. Adding BMD to FRAX® did not improve the performance of the tool in the general population.
URI: https://hdl.handle.net/10316/108360
ISSN: 2056-5933
DOI: 10.1136/rmdopen-2017-000509
Direitos: openAccess
Aparece nas coleções:FMUC Medicina - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Visualizações de página

31
Visto em 8/mai/2024

Downloads

15
Visto em 8/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons