Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/108130
Título: Novel grid combined with peripheral distortion correction for ultra-widefield image grading of age-related macular degeneration
Autor: Oellers, Patrick
Laíns, Inês 
Mach, Steven
Garas, Shady
Kim, Ivana K
Vavvas, Demetrios G
Miller, Joan W
Husain, Deeba
Miller, John B
Palavras-chave: ultra-widefield; autofluorescence; macular degeneration; grid; periphery; drusen; retinal pigment epithelium changes
Data: 2017
Editora: Dove Medical Press
Título da revista, periódico, livro ou evento: Clinical Ophthalmology
Volume: 11
Resumo: Purpose: Eyes with age-related macular degeneration (AMD) often harbor pathological changes in the retinal periphery and perimacular region. These extramacular changes have not been well classified, but may be phenotypically and functionally relevant. The purpose of this study was to demonstrate a novel grid to systematically study peripheral retinal abnormalities in AMD using geometric distortion-corrected ultra-widefield (UWF) imaging. Methods: This is a cross-sectional observational case series. Consecutive patients with AMD without any other coexisting vitreoretinal disease and control patients over age 50 without AMD or any other vitreoretinal disease were imaged using Optos 200 Tx. Captured 200° UWF images were corrected for peripheral geometric distortion using Optos transformation software. A newly developed grid to study perimacular and peripheral abnormalities in AMD was then projected onto the images. Results: Peripheral and perimacular changes such as drusen, retinal pigment epithelium changes and atrophy were found in patients with AMD. The presented grid in conjunction with geometric distortion-corrected UWF images allowed for systematic study of these peripheral changes in AMD. Conclusion: We present a novel grid to study peripheral and posterior pole changes in AMD. The grid is unique in that it adds a perimacular zone, which may be important in characterizing certain phenotypes in AMD. Our UWF images were corrected for geometric peripheral distortion to accurately reflect the anatomical dimensions of the retina. This grid offers a reliable and reproducible foundation for the exploration of peripheral retinal pathology associated with AMD.
URI: https://hdl.handle.net/10316/108130
ISSN: 1177-5467
DOI: 10.2147/OPTH.S143246
Direitos: openAccess
Aparece nas coleções:FMUC Medicina - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Visualizações de página

41
Visto em 8/mai/2024

Downloads

16
Visto em 8/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons