Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/107773
Title: Low-Cycle Fatigue Behaviour of AISI 18Ni300 Maraging Steel Produced by Selective Laser Melting
Authors: Branco, Ricardo 
Costa, José D. M. 
Berto, Filippo
Razavi, Seyed
Ferreira, José A. Martins 
Capela, Carlos 
Santos, Luís
Antunes, Fernando 
Keywords: AISI 18Ni300 steel; low-cycle fatigue; cyclic deformation behaviour; laser sintering metals; functional materials
Issue Date: 2018
Publisher: MDPI
Project: project No. 016713 (PTDC/EMS-PRO/1356/2014) financed by Project 3599: Promover a Produção Científica e Desenvolvimento Tecnológico e a Constituição de Redes Temáticas (3599-PPCDT) and FEDER funds 
Serial title, monograph or event: Metals
Volume: 8
Issue: 1
Abstract: Selective laser melting has received a great deal of attention in recent years. Nevertheless, research has been mainly focused on the technical issues and their relationship with the final microstructure and monotonic properties. Fatigue behaviour has rarely been addressed, and the emphasis has been placed on high-cycle regimes. The aim of this paper is, therefore, to study, in a systematic manner, the cyclic plastic behaviour of AISI 18Ni300 maraging steel manufactured by selective laser melting. For this purpose, low-cycle fatigue tests, under fully-reversed strain-controlled conditions, with strain amplitudes ranging from 0.3% to 1.0%, were performed. After testing, fracture surfaces were examined by scanning electron microscopy to identify the main fatigue damage mechanisms. The analysis of results showed a non-Masing material, with a slight strain-softening behaviour, and non-linear response in both the elastic and plastic regimes. In addition, this steel exhibited a very low transition life of about 35 reversals, far below the values of conventional materials with equivalent monotonic mechanical properties, which can be attributed to the combination of high strength and low ductility. The total strain energy density, irrespective of strain amplitude, revealed itself to be a quite stable parameter throughout the lifetime. Finally, the SEM analysis showed for almost all the tested samples cracks initiated from the surface and inner defects which propagated through the rest of the cross section. A ductile/brittle fracture, with a predominance of brittle fracture, was observed in the samples, owing to the presence of defects which make it easier to spread the microcracks.
URI: https://hdl.handle.net/10316/107773
ISSN: 2075-4701
DOI: 10.3390/met8010032
Rights: openAccess
Appears in Collections:I&D CEMMPRE - Artigos em Revistas Internacionais

Show full item record

Page view(s)

54
checked on Apr 24, 2024

Download(s)

37
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons