Resumo: The aim of this research was to compare the pulp temperature (PT) rise induced by four light-emitting diode light-curing units (LED LCUs) (Bluephase 20i, Demi Ultra, SPEC 3, and Valo) in different curing modes. Immediately after extraction, the pulp chamber of 11 premolars was accessed from the palatal cervical third of the crown for insertion of fiber Bragg grating (FBG) sensors for temperature measurement and kept in a 37.0° water bath. The teeth were then submitted to a random sequence of curing modes with four irradiations at 30 s intervals. Care was taken to ensure complete pulp temperature reset between curing modes. The curing modes were classified as high-energy (above 80 J/cm²) or low-energy (below 40 J/cm²) according to the total energy density delivered. Statistical analysis was performed with repeated ANOVA measures and Pearson's correlation for the association between energy density and temperature variation. The significance level was set to 0.05. All curing units promoted a statistically significant PT rise (p < 0.01). After four emissions, the PT rise was higher than 5.0 °C for the high-energy curing modes. The low-energy modes induced approximately a 2.5 °C rise. A strong positive correlation was found between energy density and PT increase (R = 0.715; p = 0.01). Exposure of intact premolars to LED LCUs induced significant and cumulative PT rise. Curing modes emitting high energy densities produced higher PT variations. Radiant exposure was positively correlated to PT variation.
URI: https://hdl.handle.net/10316/107147
ISSN: 1996-1944
DOI: 10.3390/ma12030411
Direitos: openAccess
Aparece nas coleções:FMUC Med. Dentária - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Citações SCOPUSTM   

16
Visto em 6/mai/2024

Citações WEB OF SCIENCETM

15
Visto em 2/mai/2024

Visualizações de página

67
Visto em 7/mai/2024

Downloads

28
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons