Title: Clinical performance evaluation of the Idylla™ EGFR Mutation Test on formalin-fixed paraffin-embedded tissue of non-small cell lung cancer
Authors: Delgado-García, Mercedes
Weynand, Birgit
Gómez-Izquierdo, Lourdes
Hernández, María José
Blanco, Ángela María
Varela, Mar
Matias-Guiu, Xavier
Nadal, Ernest
Márquez-Lobo, Bélgica
Alarcão, Ana 
de Álava, Enrique
Biscuola, Michele
Keywords: Non-small-cell lung carcinoma; EGFR; Mutations
Issue Date: 2020
Publisher: Springer Nature
Project: Supported by each clinical center. Biocartis provided free-of-charge Idylla™ EGFR Mutation Test cartridges. 
Serial title, monograph or event: BMC Cancer
Volume: 20
Issue: 1
Abstract: Background: Detection of epidermal growth factor receptor (EGFR) mutations in exons 18–21 is recommended in all patients with advanced Non-small-cell lung carcinoma due to the demonstrated efficiency of the standard therapy with tyrosine kinase inhibitors in EGFR-mutated patients. Therefore, choosing a suitable technique to test EGFR mutational status is crucial to warrant a valid result in a short turnaround time using the lowest possible amount of tissue material. The Idylla™ EGFR Mutation Test is a simple, fast and reliable method designed for the detection of EGFR mutations from formalin-fixed paraffin-embedded samples. The aim of this study was the Clinical Performace Evaluation of the Idylla™ EGFR Mutation Test on the Idylla™ System. Methods: EGFR mutational status was determined on 132 archived formalin-fixed paraffin-embedded tissue sections with Idylla™ technology. Results were compared with the results previously obtained by routine method in the reference lab (Therascreen® EGFR RGQ PCR v2, Qiagen in Molecular Pathology lab, Hospital Universitario Virgen del Rocío de Sevilla). Results: The overall agreement between results obtained with the Idylla™ EGFR Mutation Test and the Comparator test method was 95.38% (with 1-sided 95% lower limit of 91.7%) showing Positive Diagnostic Agreement of 93.22% and Negative Diagnostic Agreement of 97.18%, with a Limit Of Detection ≤5%. Conclusions: The Idylla™ EGFR Mutation Test passed its clinical validity performance characteristics for accuracy.
URI: https://hdl.handle.net/10316/105823
ISSN: 1471-2407
DOI: 10.1186/s12885-020-6697-7
Rights: openAccess
Appears in Collections:FMUC Medicina - Artigos em Revistas Internacionais

Show full item record

SCOPUSTM   
Citations

15
checked on Apr 29, 2024

WEB OF SCIENCETM
Citations

15
checked on Apr 2, 2024

Page view(s)

43
checked on Apr 30, 2024

Download(s)

20
checked on Apr 30, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons