Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/105333
Título: | Comparative Analysis of Morphological and Release Profiles in Ocular Implants of Acetazolamide Prepared by Electrospinning | Autor: | Morais, Mariana Coimbra, Patrícia Pina, Maria E. |
Palavras-chave: | ocular implants; electrospinning technique; glaucoma; sustained drug release; poly "-caprolactone; electrospun fibers | Data: | 15-Fev-2021 | Editora: | MDPI | Título da revista, periódico, livro ou evento: | Pharmaceutics | Volume: | 13 | Número: | 2 | Resumo: | The visual impairment that often leads to blindness causes a higher morbidity rate. The goal of this work is to create a novel biodegradable polymeric implant obtained from coaxial fibers containing the dispersed drug-acetazolamide-in order to achieve sustained drug release and increase patient compliance, which is of the highest importance. Firstly, during this work, uncoated implants were produced by electrospinning, and rolled in the shape of small cylinders that were composed of uniaxial and coaxial fibers with immobilized drug inside. The fibers were composed by PCL (poly ε-caprolactone) and Lutrol F127 (poly (oxyethylene-b-oxypropylene-b-oxyethylene)). The prepared implants exhibited a fast rate of drug release, which led to the preparation of new implants incorporating the same formulation but with an additional coating film prepared by solvent casting and comprising PCL and Lutrol F127 or PCL and Luwax EVA 3 ((poly (ethylene-co-vinyl acetate)). Implants were characterized and in vitro release profiles of acetazolamide were obtained in phosphate buffered saline (PBS) at 37 °C. The release profile of the acetazolamide from coated implant containing Luwax EVA 3 is considerably slower than what was observed in case of coated implants containing Lutrol F127, allowing a sustained release and an innovation relatively to other ocular drug delivery systems. | URI: | https://hdl.handle.net/10316/105333 | ISSN: | 1999-4923 | DOI: | 10.3390/pharmaceutics13020260 | Direitos: | openAccess |
Aparece nas coleções: | FFUC- Artigos em Revistas Internacionais FCTUC Eng.Química - Artigos em Revistas Internacionais I&D CERES - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Comparative-analysis-of-morphological-and-release-profiles-in-ocular-implants-of-acetazolamide-prepared-by-electrospinningPharmaceutics.pdf | 3.49 MB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
13
Visto em 14/out/2024
Citações WEB OF SCIENCETM
11
Visto em 2/set/2024
Visualizações de página
62
Visto em 15/out/2024
Downloads
53
Visto em 15/out/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Este registo está protegido por Licença Creative Commons