Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/103208
Título: Thermo-Energy Performance of Lightweight Steel Framed Constructions: A Case Study
Autor: Moga, Ligia
Petran, Ioan
Santos, Paulo 
Ungureanu, Viorel
Palavras-chave: LSF constructions; thermal bridging; thermal resistance; thermal transmittance; numerical simulation; thermal performance; energy performance; parametric study; nZEB; energy rating
Data: 2022
Título da revista, periódico, livro ou evento: Buildings
Volume: 12
Número: 3
Resumo: The building sector continues to play an essential role in reducing worldwide energy consumption. The reduced consumption is accompanied by stricter regulation for the thermotechnical design of the building envelope. The redefined nearly Zero Energy Building levels that will come into force for each member state will pressure designers to rethink the constructive details so that mandatory levels can be reached, without increasing the construction costs over an optimum level but at the same time reducing greenhouse gas emissions. The paper aims to illustrate the main conclusions obtained in assessing the thermo-energy performance of a steel-framed building representing a holistically designed modular laboratory located in a moderate continental temperate climate, characteristic of the south-eastern part of the Pannonian Depression with some sub-Mediterranean influences. An extensive numerical simulation of the main junctions was performed. The thermal performance was established in terms of the main parameters, the adjusted thermal resistances and global thermal insulation coefficient. Further on, the energy consumption for heating was established, and the associated energy rating was in compliance with the Romanian regulations. A parametric study was done to illustrate the energy performance of the investigated case in the five representative climatic zones from Romania. An important conclusion of the research indicates that an emphasis must be placed on the thermotechnical design of Light Steel Framed solutions against increased thermal bridge areas caused by the steel’s high thermal conductivity for all building components to reach nZEB levels. Nevertheless, the results indicate an exemplary behaviour compared to classical solutions, but at the same time, the need for an iterative redesign so that all thermo-energy performance indicators are achieved.
URI: https://hdl.handle.net/10316/103208
ISSN: 2075-5309
DOI: 10.3390/buildings12030321
Direitos: openAccess
Aparece nas coleções:I&D ISISE - Artigos em Revistas Internacionais
FCTUC Eng.Civil - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Citações SCOPUSTM   

8
Visto em 29/abr/2024

Citações WEB OF SCIENCETM

8
Visto em 2/mai/2024

Visualizações de página

79
Visto em 7/mai/2024

Downloads

95
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons