Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/100795
Título: | Thermal Performance Improvement of Double-Pane Lightweight Steel Framed Walls Using Thermal Break Strips and Reflective Foils | Autor: | Santos, Paulo Ribeiro, Telmo |
Palavras-chave: | thermal performance; experimental assessment; double-pane; lightweight steel frame (LSF); partition walls; aerogel thermal break strips; aluminium reflective foils | Data: | 2021 | Projeto: | POCI-01-0145-FEDER-032061 | Título da revista, periódico, livro ou evento: | Energies | Volume: | 14 | Número: | 21 | Resumo: | The reduction of unwanted heat losses across the buildings’ envelope is very relevant to increase energy efficiency and achieve the decarbonization goals for the building stock. Two major heat transfer mechanisms across the building envelope are conduction and radiation, being this last one very important whenever there is an air cavity. In this work, the use of aerogel thermal break (TB) strips and aluminium reflective (AR) foils are experimentally assessed to evaluate the thermal performance improvement of double-pane lightweight steel-framed (LSF) walls. The faceto- face thermal resistances were measured under laboratory-controlled conditions for sixteen LSF wall configurations. The reliability of the measurements was double-checked making use of a homogeneous XPS single panel, as well as several non-homogeneous double-pane LSF walls. The measurements allowed us to conclude that the effectiveness of the AR foil is greater than the aerogel TB strips. In fact, using an AR foil inside the air cavity of double-pane LSF walls is much more effective than using aerogel TB strips along the steel flange, since only one AR foil (inner or outer) provides a similar thermal resistance increase than two aerogel TB strips, i.e., around +0.47 m2 K/W (+19%). However, the use of two AR foils, instead of a single one, is not effective, since the relative thermal resistance increase is only about +0.04 m2 K/W (+2%). | URI: | https://hdl.handle.net/10316/100795 | ISSN: | 1996-1073 | DOI: | 10.3390/en14216927 | Direitos: | openAccess |
Aparece nas coleções: | I&D ISISE - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Thermal-performance-improvement-of-doublepane-lightweight-steel-framed-walls-using-thermal-break-strips-and-reflective-foilsEnergies.pdf | 3.78 MB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
9
Visto em 15/abr/2024
Citações WEB OF SCIENCETM
9
Visto em 2/abr/2024
Visualizações de página
63
Visto em 23/abr/2024
Downloads
68
Visto em 23/abr/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Este registo está protegido por Licença Creative Commons