Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/96798
DC FieldValueLanguage
dc.contributor.advisorGaspar, Adélio Manuel Rodrigues-
dc.contributor.advisorRodrigues, Paulo Miguel Pessoa-
dc.contributor.authorRamos, André Filipe Oliveira-
dc.date.accessioned2021-12-23T10:42:50Z-
dc.date.available2021-12-23T10:42:50Z-
dc.date.issued2015-09-
dc.identifier.urihttps://hdl.handle.net/10316/96798-
dc.descriptionDissertação de Mestrado em Engenharia do Ambiente na Especialidade de Tecnologia e Gestão do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbrapt
dc.description.abstractOs complexos desportivos com piscinas interiores requerem por norma um consumo elevado de energia térmica e elétrica, de modo a satisfazer as condições de conforto requeridas para o bem-estar dos seus utentes. A maioria destes complexos pertencem aos municípios e em Portugal estudos de eficiência energética a estes complexos são ainda raros, tornando-se assim de urgente importância a necessidade de promover estudos que contribuam para eliminar ou reduzir custos para as autarquias. Este estudo irá incidir sobre o Centro Olímpico de Piscinas Municipais de Coimbra (COPMC), considerado um dos melhores e mais modernos em Portugal. Envolve uma caraterização do edifício e dos equipamentos da instalação. São analisados os consumos de energia e de água, os respetivos custos e construídos indicadores para comparação com valores de referência. É feita a caraterização do sistema atual de iluminação e analisada a viabilidade económica da substituição por iluminação de tecnologia LED e a instalação de detetores de presença. O consumo anual total de energia elétrica obtido foi de 1083 MWh, sendo 415 MWh relativo à iluminação atual. Com a implementação do sistema de iluminação LED em conjunto com os detetores de presença consegue-se uma diminuição de 31,3 % dos consumos de energia elétrica inerentes ao sistema de iluminação, resultando numa redução anual de 130 MWh.pt
dc.description.abstractSports complex with indoor pools normally require high consumption of thermal and electric energy in order to satisfy the comfort conditions required for the well-being of the users. Most of these complexes belong to municipalities and in Portugal energy studies to these complexes are still rare, thus making it of urgent importance the need to promote studies aimed at helping to eliminate or reduce costs to municipalities. This study will focus on the Olympic Center of Municipal Swimming Pools of Coimbra (COPMC), considered one of the best and most modern in Portugal. It involves a characterization of the building and facility equipment. Consumption and costs of energy and water are analyzed and built indicators for comparison with reference values. It is made a characterization of the current lighting system and analyzed the economic viability of substitution to LED lighting technology and the installation of presence detectors. The total electricity consumption obtained was 1083 MWh, 415 MWh belonging to the currently installed lighting. With the implementation of the LED lighting system in conjunction with the presence detectors a decrease of 31,3 % in electricity consumption related to lighting is achieved, resulting in an annual reduction of 130 MWh.pt
dc.language.isoporpt
dc.rightsembargoedAccesspt
dc.subjectEficiência Energéticapt
dc.subjectPiscinas Interiorespt
dc.subjectComplexos Desportivospt
dc.subjectIluminação Eficientept
dc.subjectIluminação LEDpt
dc.subjectCustos de Energiapt
dc.subjectEnergy Efficiencypt
dc.subjectIndoor Poolspt
dc.subjectSports Complexpt
dc.subjectEfficient Lightingpt
dc.subjectLED Lightingpt
dc.subjectEnergy Costspt
dc.titleEficiência energética em complexos de piscinas interiores: Medidas de eficiência energética e análise económica ao sistema de iluminação do COPMCpt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2021-08-30*
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado em Engenharia do Ambiente-
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo2190pt
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1pt-
item.openairetypemasterThesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
crisitem.advisor.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.advisor.orcid0000-0001-6947-4579-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
Show simple item record

Page view(s)

87
checked on May 7, 2024

Download(s)

95
checked on May 7, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.