Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/93598
Title: Análise de estratégias de controlo de iluminação e ventilação num edifício escolar
Other Titles: Analysis of lighting and ventilation control strategies in a school building
Authors: Silva, Nelson Simões
Orientador: Gaspar, Adélio Manuel Rodrigues
Rodrigues, Eugénio Miguel de Sousa
Keywords: AVAC; Iluminação; Ventilação; QAI; Conforto térmico; HVAC; Lighting; Ventilation; Indoor Air Quality; Thermal comfort
Issue Date: 30-Sep-2019
Serial title, monograph or event: Análise de estratégias de controlo de iluminação e ventilação num edifício escolar
Place of publication or event: Departamento de Engenharia Mecânica
Abstract: Este trabalho tem como principal objetivo estudar várias estratégias de controlo de iluminação e ventilação num edifício escolar. Importa, portanto, compreender formas de cumprir a regulamentação, assegurar o conforto térmico e visual, a qualidade do ar interior e minimizar o custo de exploração dos sistemas de climatização. No campo de iluminação, partindo de uma situação de sobredimensionamento das luminárias, realizou-se um estudo de influência da iluminação no conforto visual dos ocupantes e, evidentemente da sua cota parte nos consumos energéticos do edifício.No âmbito da climatização eficiente dos espaços, dimensionaram-se, no programa de simulação energética DesignBuilderTM, sistemas de climatização com funcionamento VAC (Volume de Ar Constante) e VAV (Volume de Ar Variável). No primeiro caso consideraram-se duas situações, uma em que a QAN (quantidade de ar novo) é constante e determinada recorrendo a duas metodologias previstas na regulamentação, método prescritivo e método analítico, e uma segunda em que a QAN é variável e dependente da ocupação dos espaços. No segundo caso, considerou-se duas situações, uma com QAN constante, e outra com a QAN variável em função da carga térmica. O restante caudal para garantir o volume de insuflação pretendido fica ao encargo do ar de recirculação.Para terminar, analisaram-se os consumos energéticos de cada um dos sistemas descritos de forma a avaliar qual seria a melhor solução para o caso em estudo, quer a nível de eficiência energética, quer a nível de proporcionar conforto térmico, e visual, aos ocupantes e garantir a qualidade do ar interior.
The main goal of this work is to study several lighting and ventilation control strategies in a school building. Therefore, is crucial to understand how to ensure thermal and visual comfort and indoor air quality, all while minimizing the HVAC systems costs and comply with all legal regulations applied.In the lighting field, starting from a situation of oversized lamps, a lighting influence study, on the visual comfort of the occupants, was conducted, and, naturally its influence on the energy consumption of the building. To ensure the climatization on the occupied areas, several systems were dimensioned on the energy simulation program DesignBuilderTM, with different functioning principles, one with CAV (Constant Air Volume) and another with VAV (Variable Air Volume). In the first case two different situations were considered, one where the outdoor air volume is constant and determined by two methodologies present in legislation, the prescriptive method and the analytic method, and a second one where the outdoor air volume is variable and function of the space occupation rate. In the second case, two distinct cases applied, one where the outdoor air is constant and another where the outdoor air is dependent on the thermal load of the space. Recirculation air is in charge of ensuring the remaining air volume to achieve the pretended insufflation volume.Last, the energy consumption of every system was analyzed in order to evaluate the best solution to achieve a good energy efficiency, deliver thermal and visual comfort to the occupants e ensure a good indoor air quality.
Description: Dissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/93598
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Show full item record

Page view(s)

150
checked on Apr 16, 2024

Download(s)

292
checked on Apr 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons