Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/93145
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ferreira, Elisa | - |
dc.contributor.author | Real, Francisco Corte | - |
dc.contributor.author | Melo, Teresa Pinho e | - |
dc.contributor.author | Margalho, Cláudia | - |
dc.date.accessioned | 2021-02-17T11:55:41Z | - |
dc.date.available | 2021-02-17T11:55:41Z | - |
dc.date.issued | 2020-12-12 | - |
dc.identifier.issn | 0146-4760 | pt |
dc.identifier.issn | 1945-2403 | pt |
dc.identifier.uri | https://hdl.handle.net/10316/93145 | - |
dc.description.abstract | Opioids are the drugs most commonly detected in overdose deaths and the second most consumed worldwide. An analytical methodology has been optimized and fully validated for the determination of codeine, morphine, 6-acetylmorphine, 6-acetylcodeine, oxycodone, oxymorphone and fentanyl in whole blood and pericardial fluid. The internal standards used were codeine-d3, morphine-d3, 6-acetylmorphine-d3 and fentanyl-d5. Before solid-phase extraction, volumes of 250 μL of blood and pericardial fluid were subjected to a protein precipitation (with 750 μL of ice-cold acetonitrile) and a microwave-induced oximation was performed using a solution of 1% aqueous hydroxylamine hydrochloride in phosphate-buffered saline (1:2, v/v). Finally, the dried extracts were further derivatized with a solution of n-methyl-n-(trimethylsilyl) trifluoroacetamide + 5% trimethylchlorosilane under microwave irradiation. The chromatographic analysis was carried out using gas chromatography-mass spectrometry operating in electron impact and selected ion monitoring mode. For all analytes, the method was linear between 5 and 1,000 ng/mL with determination coefficients (r2) >0.99. Depending on the analyte and matrix, the limit of detection varies between 3 and 4 ng/mL. Intra- and intermediate precision (<20%) and bias (±20%) were acceptable for all analytes in both matrices. The stability of the substances in the studied matrices was guaranteed, at least, 24 h in the autosampler, 4 h at room temperature and 30 days after three freeze/thaw cycles. This methodology was applied to real samples from the Laboratory of Chemistry and Forensic Toxicology, Centre Branch, of the National Institute of Legal Medicine and Forensic Sciences, Portugal. | pt |
dc.language.iso | eng | pt |
dc.rights | embargoedAccess | pt |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | pt |
dc.subject.mesh | Analgesics, Opioid | pt |
dc.subject.mesh | Drug Overdose | pt |
dc.subject.mesh | Fentanyl | pt |
dc.subject.mesh | Humans | pt |
dc.subject.mesh | Oxycodone | pt |
dc.subject.mesh | Pericardial Fluid | pt |
dc.subject.mesh | Substance Abuse Detection | pt |
dc.subject.mesh | Forensic Toxicology | pt |
dc.title | A Novel Bioanalytical Method for the Determination of Opioids in Blood and Pericardial Fluid | pt |
dc.type | article | - |
degois.publication.firstPage | 754 | pt |
degois.publication.lastPage | 768 | pt |
degois.publication.issue | 8 | pt |
degois.publication.title | Journal of Analytical Toxicology | pt |
dc.relation.publisherversion | https://academic.oup.com/jat/article-abstract/44/8/754/5855107 | pt |
dc.peerreviewed | yes | pt |
dc.identifier.doi | 10.1093/jat/bkaa064 | pt |
degois.publication.volume | 44 | pt |
dc.date.embargo | 2021-12-12 | * |
uc.date.periodoEmbargo | 365 | pt |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.researchunit | CQC - Coimbra Chemistry Centre | - |
crisitem.author.parentresearchunit | Faculty of Sciences and Technology | - |
crisitem.author.orcid | 0000-0003-1495-9362 | - |
crisitem.author.orcid | 0000-0003-3256-4954 | - |
Appears in Collections: | I&D CQC - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Ferreira2020JAnalTox.pdf | 2.82 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
2
checked on Oct 14, 2024
WEB OF SCIENCETM
Citations
2
checked on Oct 2, 2024
Page view(s)
172
checked on Oct 15, 2024
Download(s)
221
checked on Oct 15, 2024
Google ScholarTM
Check
Altmetric
Altmetric
This item is licensed under a Creative Commons License