Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/92116
DC FieldValueLanguage
dc.contributor.advisorAndrade, Anísio Alberto Martinho de-
dc.contributor.advisorCosta, Paulo Manuel Mendes Pinheiro da Providência e-
dc.contributor.authorHenriques, Ana Mafalda de Carvalho-
dc.date.accessioned2020-12-15T04:01:29Z-
dc.date.available2020-12-15T04:01:29Z-
dc.date.issued2020-11-18-
dc.date.submitted2020-12-15-
dc.identifier.urihttps://hdl.handle.net/10316/92116-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia-
dc.description.abstractA ação sísmica pode ter efeitos muito significativos em grande parte do território nacional, tendo de ser considerada na avaliação da segurança, condições de serviço e outros parâmetros associados ao desempenho estrutural. Porém, uma grande parte do edificado em território nacional foi erigida antes de meados da década de 1980, altura a partir da qual a legislação passou a contemplar de forma adequada a ação sísmica. Ou seja, são muitas as construções cuja segurança relativa à ação sísmica deveria ser avaliada e que, eventualmente, deveriam ser sujeitas a uma intervenção de reabilitação sísmica.O isolamento sísmico ou isolamento de base é uma técnica cuja aplicação ao setor da construção, e dos edifícios em particular, é relativamente recente. Popularizou-se primeiro no Japão, mas rapidamente se expandiu, atingindo muitas outras regiões como os EUA, que abordaram a técnica seriamente com generosas campanhas de investigação que culminaram num corpo regulamentar robusto, e também a Europa, particularmente a Itália, cujo edificado apresenta bastantes semelhanças com o nosso. O motivo do relativo sucesso desta técnica, particularmente na área da reabilitação (embora seja igualmente interessante para novas edificações), deve-se (i) à intervenção no edifício ser relativamente localizada, (ii) a existirem diversas soluções disponíveis no mercado, não apenas de produtos, mas de empresas de construção aptas, e (iii) à análise e dimensionamento (pelo menos a fase de pré-dimensionamento geral, como se concluiu neste trabalho) se basearem num modelo simples e em cálculos também acessíveis. Esta combinação de fatores resulta numa opção de reabilitação sísmica fortemente competitiva, quando não vedada pelas condições do terreno.Neste trabalho apresenta-se uma visão genérica do isolamento sísmico de base como técnica de reabilitação estrutural sísmica, e, a título de exemplo, aplica-se o isolamento de base à estrutura de um edifício dimensionado numa disciplina do curso, efetuando-se a análise e pré-dimensionamento da solução com base no método simplificado do Eurocódigo 8 - Parte1. Este exemplo é acompanhado da análise e discussão de alguns aspetos importantes relativos a esta técnica e, nomeadamente, ao próprio método simplificado.por
dc.description.abstractSeismic actions can have very significant effects in much of the national territory, and they must be considered for the purpose of assessing safety, service conditions and other parameters associated with structural performance. However, a large part of the building stock in Portugal was erected before the mid-1980s, hence before the legislation started to satisfactorily consider seismic actions. In other words, there are many constructions whose safety with respect to seismic actions should be assessed and possibly subject to retrofitting.Base isolation is a technique whose application in the construction industry is relatively recent, in particular to buildings. It first became popular in Japan, but quickly disseminated to other regions of the globe, such as the USA, which took the technique seriously with generous research campaigns that culminated in a robust regulatory framework, and Europe, particularly Italy, which shares many similarities with our country with regard to building stock.The relative success of this technique, particularly in the area of structural retrofitting (although it is also interesting for new buildings), is due to (i) the intervention in the building being relatively localized, (ii) the availability of solutions on the market, both in terms of systems and qualified contractors, and (iii) the simplicity of the model and calculations on which the general pre-design phase, at least, can be based (as concluded in this work). This combination of factors results in a highly competitive seismic retrofitting solution, when not limited by ground conditions.This work presents an overview of base isolation as a seismic retrofitting technique. As a case study, base isolation is applied to a reinforced concrete building structure designed, without base isolation, in a previous curricular unit of the master’s degree syllabus. The simplified method of Eurocode 8 – Part 1 is used to model and design the base isolation system. This case study motivates the discussion of certain aspects related to the technique itself and to the simplified method in particular.eng
dc.language.isopor-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectReabilitação Sísmicapor
dc.subjectEdifícios de Betão Armadopor
dc.subjectIsolamento de Basepor
dc.subjectApoios de Borracha com Núcleo de Chumbopor
dc.subjectAnálise Linear Simplificadapor
dc.subjectSeismic Retrofittingeng
dc.subjectReinforced Concrete Buildingseng
dc.subjectBase Isolationeng
dc.subjectLead Rubber Bearingseng
dc.subjectSimplified Linear Analysiseng
dc.titleIsolamento de Base para Reabilitação Sísmica de Edifícios de Betão Armadopor
dc.title.alternativeBase Isolation for Seismic Retrofitting of Reinforced Concrete Buildingseng
dc.typemasterThesis-
degois.publication.locationDEC-FCTUC-
degois.publication.titleIsolamento de Base para Reabilitação Sísmica de Edifícios de Betão Armadopor
dc.peerreviewedyes-
dc.identifier.tid202553507-
thesis.degree.disciplineEngenharia Civil-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Civil-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Engenharia Civil-
uc.degree.grantorID0500-
uc.contributor.authorHenriques, Ana Mafalda de Carvalho::0000-0003-3882-4155-
uc.degree.classification19-
uc.degree.presidentejuriCoelho, Paulo Alexandre Lopes Figueiredo-
uc.degree.elementojuriFerreira, Carla Maria Araújo Fernandes da Costa-
uc.degree.elementojuriCosta, Paulo Manuel Mendes Pinheiro da Providência e-
uc.contributor.advisorAndrade, Anísio Alberto Martinho de-
uc.contributor.advisorCosta, Paulo Manuel Mendes Pinheiro da Providência e-
item.openairetypemasterThesis-
item.languageiso639-1pt-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
crisitem.advisor.deptFaculty of Sciences and Technology-
crisitem.advisor.parentdeptUniversity of Coimbra-
crisitem.advisor.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.advisor.orcid0000-0002-3799-3902-
crisitem.advisor.orcid0000-0002-8195-1929-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
Show simple item record

Page view(s)

145
checked on Mar 26, 2024

Download(s)

314
checked on Mar 26, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons