Title: Sistema de gestão técnica do Departamento de Engenharia Electrotécnica e de Computadores
Other Titles: Building Management System of Department of Electrical and Computer Engineering
Authors: Silva, Ana Rita Rodrigues da 
Orientador: Jorge, Humberto Manuel Matos
Keywords: Sistema de Gestão Técnica; Unity Pro; Interface Homem Máquina; SCADA; Visu+; Building Management System; Unity Pro; Human Machine Interface; SCADA; Visu+
Issue Date: 22-Feb-2019
Serial title, monograph or event: Sistema de gestão técnica do Departamento de Engenharia Electrotécnica e de Computadores
Place of publication or event: DEEC
Abstract: Atualmente a sociedade depara-se com uma utilização de energia elétrica sem precedentes assente numa economia exposta à volatilidade do preço do petróleo, fortemente relacionada com o preço do gás natural e do carvão. Essa mudança de paradigma deve-se em grande parte à dependência tecnológica que se instaurou no quotidiano de todos nós, e que tem originado debates e medidas de implementação que estão a reforçar a política de Utilização Racional de Energia. Neste sentido os Sistemas de Gestão Técnica dos edifícios passaram por uma enorme evolução e reconhecimento ao longo dos últimos anos. Atualmente, apresentam-se como uma ferramenta essencial na melhoria da performance dos edifícios em termos energéticos e podem revelar-se bastante úteis na redução de custos, no auxílio à manutenção dos equipamentos do edifício e na garantia de conforto e segurança dos seus utilizadores.No edifício do Departamento de Engenharia Electrotécnica e de Computadores, da Faculdade de Ciência e Tecnologias da Universidade de Coimbra, foi instalado, aquando a sua construção, um sistema de gestão técnica. No entanto, a falta de manutenção e atualização ao longo dos últimos anos culminaram na existência de um SGT desatualizado, sem supervisão e aquém das suas reais potencialidades.Assim, o objetivo principal desta dissertação é a remodelação e evolução do atual SGT após o levantamento exaustivo das condições atuais dos sistemas existentes no edifício. O trabalho desenvolvido passa, mais concretamente, por dotar o sistema de mais capacidades, permitindo-nos controlar e monitorizar todos os equipamentos pertencentes à iluminação de circulação, de forma direta ou condicionada, tanto pelos interruptores crepusculares e os detetores de ocupação como por definição de horários. Adicionalmente foi feita uma alteração ao controlo do sistema de climatização do edifício, por este não se encontrar operacional.
We are currently facing an unprecedented use of electric energy based on an economy susceptible to oil price volatility, which is strongly linked to the price of natural gas and coal. This paradigm change is largely due to the dependence on technology in our daily lives which has led to many discussions and to the implementation of measures in order to strengthen the Rational Use of Energy policy.In line with this, the Building Management System (BMS) have had a major devolvement and increased recognition over the last few years. They are currently a key tool in improving energy efficiency in buildings and can prove to be quite useful in increasing savings, helping to maintain the equipment of the building and assuring comfort and safety to its users.In the Department of Electrical and Computer Engineering, Faculty of Sciences and Technology of the University of Coimbra, at the time of the building’s construction, a BMS was installed. However, the lack of maintenance and updating over the years have resulted in an outdated and unsupervised BMS behind its real potential.Thus, the main goal of this dissertation is the redesigning and evolution of the current BMS after completing an exhaustive research of the current conditions of the existing systems in the building. The work performed consists, in particular, of equipping the system with more capabilities, enabling us to control and monitor all the equipment that comprises the circulation lighting, either directly or in a limited way. This includes not only the twilight switches and occupancy sensors, but also the configuration of schedules. Additionally, the building’s air conditioning system was restructured since it was not in working condition.
Description: Dissertação de Mestrado Integrado em Engenharia Electrotécnica e de Computadores apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/86572
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
File Description SizeFormat
dissertacao_anarita_2009107646.pdf3.37 MBAdobe PDFView/Open
Show full item record

Page view(s) 50

399
checked on Apr 16, 2024

Download(s) 50

429
checked on Apr 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons