Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/86516
Title: Indicadores para sistemas de monitorização de consumos
Other Titles: Indicators for consumption monitoring systems
Authors: Neves, Daniela Temudo 
Orientador: Jorge, Humberto Manuel Matos
Keywords: Sistema de monitorização; Indicadores; Parametrização; Gestão de energia; Eficiência energética; Monitoring System; Key Performance Indicators; Parameterization; Energy Management; Energy Efficiency
Issue Date: 19-Sep-2018
Serial title, monograph or event: Indicadores para sistemas de monitorização de consumos
Place of publication or event: DEEC
Abstract: Devido à evolução dos Sistemas de Monitorização de energia a diversidade de aplicações que existem no mercado aumentou, tendo estes cada vez mais funcionalidades. No entanto, este tema permanece actual e será abordado neste trabalho com o objectivo de melhorar e tornar estes sistemas com mais funcionalidades com a criação de novos indicadores e parâmetros. Em foco, o trabalho é elaborado em torno, do sistema MEWaGO, já implementado no Departamento de Engenharia Electrotécninca e de Computadores da Universidade de Coimbra. Com o intuito de avaliar o desempenho do sistema e permitir ao gestor analisar o comportamento do edifício, o trabalho foca a criação de uma série de indicadores que permitem a comparação de dados obtidos em estruturas semelhantes ou com valores anteriores, são eficazes e de fácil compreensão e permitem avaliar a eficiência energética e as poupanças obtidas.Do ponto de vista da parametrização, são definidos vários parâmetros necessários às especificações do sistema relacionado com a instalação. Quando se pretende ter um sistema o mais flexível possível é imperativo o estabelecimento de vários padrões e variáveis que melhorem o produto, adequando o sistema de monitorização à infraestrutura onde se insere. Outra funcionalidade concebida foi a possibilidade de o sistema conseguir gerar alertas e relatórios, aplicação importante pois, estes, têm como objectivo alertar o gestor para ocorrências que vão existindo no edifício e apresentação de um conjunto de informações reportando resultados parciais e totais recolhidos pelo sistema. Além disso, os alertas, permitem ao gestor agir atempadamente sobre as condições de funcionamento do edifício.O sistema tem de ter a capacidade de armazenamento de dados, estes valores, caso se mantenham com a resolução inicial de 15 em 15 minutos utilizam muita capacidades de armazenamento, tornam o processamento mais moroso. Assim a compressão de dados vem com o propósito de tornar o sistema mais operacional e menos consumidor de capacidade de armazenamento, colmatando assim uma das maiores falhas constatadas no sistema MEWaGO. A criação de indicadores de energia e parametrização resultou na demonstração de um sistema de monitorização de energia versátil e funcional, tendo em conta os já existentes no mercado.
Due to the evolution of Energy Monitoring Systems, the diversity of applications that exist in the market has increased, possessing more functionalities with time. However, this topic remains current and will be approached in this work with the aim of improving and making these systems more functional with the creation of new indicators and parameters. Essentially, this work concerns the MEWaGO system, already implemented in the Department of Electrical Engineering and Computers of the University of Coimbra.In order to evaluate the performance of the system and allow the manager to analyse the behavior of the building, the work focuses on the creation of a series of indicators that allow the comparison of data obtained in similar structures or with previous values, these are effective and easy to understand and allow to evaluate the obtained energy efficiency and savings.From the parameterization point of view, several parameters necessary for the specifications of the monitoring system related to the installation are defined. When it is intended to have a system as flexible as possible, it is imperative to establish several standards and variables that improve the product, adapting the monitoring system to the infrastructure where it is inserted. Another functionality conceived was the possibility of the system being able to generate alerts and reports, being an important application because these are aimed at alerting the manager to occurrences that exist in the building and presenting a set of information reporting partial and total results collected by the system. In addition, the alerts allow the manager to act in a timely manner regarding the building's operating conditions.The system must have the capacity to store data. These values, if they remain with the initial setting of collecting a value every 15 minutes, decreases its storage capacities, making data processing more time consuming. So, the data compression comes with the purpose of making the system more operational and less consuming of storage capacity, thus solving one of the biggest flaws detected in the MEWaGO system.The creation of energy indicators and parameterization resulted in the demonstration of a versatile and functional energy monitoring system, considering those already in the market.
Description: Dissertação de Mestrado Integrado em Engenharia Electrotécnica e de Computadores apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/86516
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
File Description SizeFormat
Daniela Temudo.pdf50.04 kBAdobe PDFView/Open
Show full item record

Page view(s) 50

414
checked on Jul 16, 2024

Download(s) 50

343
checked on Jul 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons