Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/86203
DC FieldValueLanguage
dc.contributor.advisorCardoso, João Manuel Rendeiro-
dc.contributor.advisorVaz, Pedro Guilherme da Cunha Leitão Dias-
dc.contributor.authorReis, Ana Luísa dos Santos-
dc.date.accessioned2019-03-27T23:20:16Z-
dc.date.available2019-03-27T23:20:16Z-
dc.date.issued2018-09-14-
dc.date.submitted2019-03-27-
dc.identifier.urihttps://hdl.handle.net/10316/86203-
dc.descriptionTrabalho de Projeto do Mestrado Integrado em Engenharia Biomédica apresentado à Faculdade de Ciências e Tecnologia-
dc.description.abstractO principal objetivo deste trabalho consistiu na avaliação do dispositivo Leap Motion Controller (LMC) enquanto técnica auxiliar de diagnóstico da doença de Parkinson (PD). Inicialmente, analisou-se a exatidão e precisão em condições estáticas e dinâmicas, estimadas pelo desvio padrão amostral e o valor RMSE, respetivamente. Em ambientes estáticos obteve-se uma precisão inferior a 0,85 mm, e verificou-se uma correlação positiva fraca entre a precisão e a distância entre o LMC e o fantoma. Em situações dinâmicas, a precisão foi inferior 1,2 mm. Na generalidade dos dados, verificou-se uma precisão melhor nos eixos segundo x e z, em detrimento do eixo segundo y.Relativamente à exatidão, em movimentos lineares obtiveram-se resultados inferiores a 2,37 mm e em rotações inferiores a 3°. Ainda, obteve-se um coeficiente de correlação de 1 entre ângulos esperados e obtidos, calculando-se uma reta de calibração para rotações em torno de z.Posteriormente, desenvolveram-se 3 interfaces interativas que possibilitaram a simulação de técnicas médicas de despiste do tremor de repouso, do tremor postural e da bradicinésia, sintomas muito frequentes da PD. Apresentaram-se os 3 testes a uma amostra da população saudável (31 indivíduos) e a 1 doente diagnosticado com PD. Relativamente ao domínio das frequências, demonstrou-se que o intervalo entre 0,5 e 3,5 Hz é o representativo do tremor de repouso e do tremor postural no grupo de controlo. No que concerne à bradicinésia, verificou-se que as frequências dominantes para indivíduos saudáveis distribuíram-se entre 1,2 e 3,7 Hz. Ainda, na avaliação da bradicinésia constatou-se que o doente apresentou alterações significativas na maioria dos parâmetros analisados. Assim, demonstrou-se que este sintoma poderá ser analisado sob efeitos farmacológicos. Por fim, concluiu-se que o LMC tem potencial para a deteção dos sintomas da PD. Contudo, mais estudos em indivíduos saudáveis e diagnosticados com PD são requeridos.por
dc.description.abstractThe main goal of this study is to evaluate the Leap Motion Controller’s (LMC) capabilities to develop a new method for the assessment of Parkinson's Disease (PD). First, the device was tested to calculate its accuracy and precision in static and dynamic conditions, estimated using the sample’s standard deviation and the RMSE value, respectively. In static environments the precision values were under 0.85mm, with verifiable weak positive correlation between the precision and the distance between the LMC and the phantom. In dynamic environments, the precision values were under 1.2 mm. In most cases, the precision was better in x and z axis, when compared to the y axis.Regarding the accuracy, the results were under 2.37 mm in linear motions and rotations under 3°. The Spearman correlation coefficient was 1 between the expected and obtained angles, leading to a calibration line for rotations on the z axis.Three interactive interfaces that allow the simulation of medical techniques were developed. These applications assessed the bradykinesia and the rest and postural tremor, which are PD’s common symptoms. The tests were conducted on a sample of 31 healthy individuals and one patient diagnosed with PD. In the frequency domain, it was proven that the interval between 0.5 and 3.5 Hz was characteristic to the control group’s rest and postural tremors. Regarding the bradykinesia, the results showed that the dominating frequencies for healthy individuals were distributed between 1.2 and 3.7 Hz. Furthermore, the patient had significant changes in a great part of the analysed parameters regarding the bradykinesia’s evaluation. Therefore, it was proven that this symptom may be analysed under pharmacologic effects. The data obtained from the healthy part of the study group was within the established values, which may suggest that the LMC can be used to detect the symptoms of PD, although, some more study group tests are advisable.eng
dc.language.isopor-
dc.rightsembargoedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/-
dc.subjectLeap Motion Controllerpor
dc.subjectmedição da precisão e exatidãopor
dc.subjectdoença de Parkinsonpor
dc.subjecttremorpor
dc.subjectbradicinésiapor
dc.subjectLeap Motion Controllereng
dc.subjectprecision and accuracy measurementeng
dc.subjectParkinson’s diseaseeng
dc.subjecttremoreng
dc.subjectbradykinesiaeng
dc.titleAplicação do Leap Motion na avaliação da doença de Parkinsonpor
dc.title.alternativeLeap motion controller as a sensor for Parkinson's disease assessmenteng
dc.typemasterThesis-
degois.publication.locationLIBPhys-
degois.publication.titleAplicação do Leap Motion na avaliação da doença de Parkinsonpor
dc.date.embargoEndDate2019-03-13-
dc.peerreviewedyes-
dc.date.embargo2019-03-13*
dc.identifier.tid202206190-
thesis.degree.disciplineEngenharia Biomédica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Biomédica-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Física-
uc.degree.grantorID0500-
uc.contributor.authorReis, Ana Luísa dos Santos::0000-0001-5158-1413-
uc.degree.classification19-
uc.date.periodoEmbargo180-
uc.degree.presidentejuriFerreira, Nuno David Sousa Chichorro Fonseca-
uc.degree.elementojuriMorgado, António Miguel Lino Santos-
uc.degree.elementojuriVaz, Pedro Guilherme da Cunha Leitão Dias-
uc.contributor.advisorCardoso, João Manuel Rendeiro::0000-0002-8832-8208-
uc.contributor.advisorVaz, Pedro Guilherme da Cunha Leitão Dias::0000-0003-3490-7789-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
crisitem.advisor.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.advisor.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.advisor.parentresearchunitUniversity of Coimbra-
crisitem.advisor.parentresearchunitUniversity of Coimbra-
crisitem.advisor.orcid0000-0002-8832-8208-
crisitem.advisor.orcid0000-0003-3490-7789-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Dissertacao_Ana_Reis.pdf9.82 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

463
checked on Apr 23, 2024

Download(s) 50

537
checked on Apr 23, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons