dc.description.abstractA EDP Distribuição é o Operador de Rede de Distribuição, responsável pela distribuição de energia elétrica em Portugal Continental. Com o fim de garantir os níveis de continuidade e qualidade de serviço, obrigatórios por lei, realizou um forte investimento na implementação de uma rede privativa de fibra ótica para suporte dos sistemas de telecomunicações, possibilitando assim o controlo e supervisão das suas instalações técnicas como Subestações (AT/MT) e de Órgão de Corte de Rede de Média Tenção, a partir de uma gestão centralizada. Este passo, foi uma grande mais valia para flexibilidade e fiabilidade da rede de distribuição elétrica.Este trabalho teve como principal motivação, a construção de um modelo de cálculo para a Manutenção Preventiva Sistemática da infraestrutura de fibra ótica de um Operador de Rede de Distribuição, a EDP Distribuição, baseada numa politica de manutenção Condition Based Risk Maintenance (CBRM).Tendo como base as metodologias existentes e as que ainda se encontram em fase de desenvolvimento relativas à gestão de ativos técnicos, foram identificados os fatores mensuráveis que influenciam os cabos de fibra ótica, e criado um modelo heurístico para aferir o Índice de Saúde e a Probabilidade de Falha, de uma forma real e exequível.Com o objetivo inicial de criar um plano de Manutenção Preventiva Sistemática baseado na condição e no risco, foi realizado um levantamento e tipificada a criticidade afeta a cada ligação de fibra.Após recolha dos indicadores inerentes ao Índice de Saúde, à Probabilidade de Falha e à criticidade, foi possível criar um modelo matemático, recorrendo à Teoria dos Grafos, para implementar uma politica de manutenção baseada em CBRM, que reflete de forma eficaz o estado atual, e permite prever o estado futuro do ativo técnico em causa.por
dc.description.abstractEDP Distribuição is the Distribution Network Operator, responsible for the distribution of electricity in mainland Portugal. In order to guarantee the levels of continuity and quality of service, legally required, it made a strong investment in the implementation of a private fiber optic network to support telecommunications systems, thus enabling the control and supervision of its technical installations as Substations (HV/MV) and Medium Voltage Remote Switchgear, from a centralized management. This step was a great improvement to the flexibility and reliability of the electrical distribution network.This project had as main motivation, the development of a calculation model to the Systematic Preventive Maintenance of the fiber optic infrastructure of a Distribution Network Operator, the EDP Distribuição, based on a Condition Based Risk Maintenance (CBRM) maintenance policy.Based on existing methodologies and those still in the development phase related to the management of technical assets, were identified measurable factors that influence the fiber optic cables were identified, and was created a heuristic model to get the Health Index and the Probability of Failure, in a realistic and workable way.With the initial objective of creating a Systematic Preventive Maintenance plan based on the condition and the risk, a survey was carried out and typified the criticality that affects each fiber connection.After gathering the indicators inherent to the Health Index, Failure Probability and Criticality, it was possible to create a mathematical model, using Graph Theory, to implement a CBRM based maintenance policy, that effectively reflects the current state, and allows to predict the future state of the technical asset in question.eng
dc.language.isopor-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectManutenção Preventiva Sistemáticapor
dc.subjectFibra Óticapor
dc.subjectPolitica de Manutenção - Condition Based Risk Maintenancepor
dc.subjectGestão de Ativospor
dc.subjectÍndice de Saúde/Probabilidade de Falhapor
dc.subjectSystematic Preventive Maintenanceeng
dc.subjectFiber Opticseng
dc.subjectMaintenance Policy - Condition Based Risk Maintenanceeng
dc.subjectAsset Managementeng
dc.subjectHealth Index/Probability of Failureeng
dc.titleManutenção Preventiva das Infraestruturas de Fibra Ótica da EDP Distribuiçãopor
dc.title.alternativePreventive Maintenance of EDP Distribuição Fiber Optic Infrastructureseng
dc.typemasterThesis-
degois.publication.locationDEEC-
degois.publication.titleManutenção Preventiva das Infraestruturas de Fibra Ótica da EDP Distribuiçãopor
dc.peerreviewedyes-
dc.identifier.tid202126366-
thesis.degree.disciplineEngenharia Electrotécnica e de Computadores-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Electrotécnica e de Computadores-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Eng. Electrotécnica e de Computadores-
uc.degree.grantorID0500-
uc.contributor.authorFonseca, Pedro José Batalha da::0000-0003-3951-4466-
uc.degree.classification17-
uc.degree.presidentejuriMedeiros, Maria do Carmo Raposo de-
uc.degree.elementojuriSilva, Henrique José Almeida da-
uc.degree.elementojuriCruz, Luís Alberto da Silva-
uc.contributor.advisorSilva, Henrique José Almeida da-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Dissertação Mestrado Pedro Fonseca-DEEC-FCTUC.pdf5.65 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

533
checked on Apr 16, 2024

Download(s) 50

1,776
checked on Apr 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons