Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/7774
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pauliukaite, Rasa | - |
dc.contributor.author | Schoenleber, Monika | - |
dc.contributor.author | Vadgama, Pankaj | - |
dc.contributor.author | Brett, Christopher | - |
dc.date.accessioned | 2009-02-17T10:33:48Z | - |
dc.date.available | 2009-02-17T10:33:48Z | - |
dc.date.issued | 2008 | en_US |
dc.identifier.citation | Analytical and Bioanalytical Chemistry. 390:4 (2008) 1121-1131 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/7774 | - |
dc.description.abstract | Abstract Protective polymer coatings have been used to enhance the retention of enzymes in sol-gel films as immobilisation phases in electrochemical biosensors. Carbon film electrodes were electrochemically modified with poly(neutral red) (PNR). These electrodes were coated with oxysilane sol-gels incorporating glucose oxidase and an outer coating of carboxylated PVC (CPVC) or polyurethane (PU), with and without Aliquat-336 or isopropyl myristate (IPM) plasticizer, was applied. The biosensors were characterised electrochemically using cyclic voltammetry and amperometry, electrochemical impedance spectroscopy and scanning electron microscopy. Impedance spectra showed that the electrode surface is most active when the sol-gel–GOx layer is not covered with a membrane. However, membranes without plasticizer extend the lifetime of the biosensor to more than 2 months when PU is used as an outer membrane. The linear range of the biosensors was found to be 0.05–0.50 mM of glucose and the biosensor with PU outer membrane exhibited higher sensitivity (ca.117 nA mM-1) in the region of linear response than that with CPVC. The biosensors were applied to glucose measurement in natural samples of commercial orange juice. | en_US |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.title | Development of electrochemical biosensors based on sol-gel enzyme encapsulation and protective polymer membranes | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1007/s00216-007-1756-3 | en_US |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.orcid | 0000-0002-1972-4434 | - |
Appears in Collections: | FCTUC Química - Artigos em Revistas Internacionais |
SCOPUSTM
Citations
38
checked on Oct 14, 2024
WEB OF SCIENCETM
Citations
5
30
checked on Oct 2, 2024
Page view(s)
275
checked on Oct 15, 2024
Download(s)
397
checked on Oct 15, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.