Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/5053
DC FieldValueLanguage
dc.contributor.authorBarsan, Madalina M.-
dc.contributor.authorKlincar, Janja-
dc.contributor.authorBatic, Martin-
dc.contributor.authorBrett, Christopher M. A.-
dc.date.accessioned2008-09-01T15:03:08Z-
dc.date.available2008-09-01T15:03:08Z-
dc.date.issued2007en_US
dc.identifier.citationTalanta. 71:5 (2007) 1893-1900en_US
dc.identifier.urihttps://hdl.handle.net/10316/5053-
dc.description.abstractA flow cell has been designed for use with an electrochemical enzyme biosensor, based on low-cost carbon-film electrodes. Three types of mediators were used: cobalt and copper hexacyanoferrates and poly(neutral red) (PNR), covered with glucose oxidase (GOx) immobilised by cross-linking with glutaraldehyde in the presence of bovine serum albumin or inside a oxysilane sol-gel network. Mixtures of sol-gel precursors were made from 3-aminopropyl-triethoxysilane (APTOS) together with methyltrimethoxysilane (MTMOS), methyltriethoxysilane (MTEOS), tetraethyloxysilane (TEOS) or 3-glycidoxypropyl-trimethoxysilane (GOPMOS), and the best chosen for encapsulation. Optimisation in batch mode, using amperometric detection at fixed potential, showed the PNR-GOx modified carbon-film electrodes to be best for flow analysis for both glutaraldehyde and sol-gel enzyme immobilisation. Both types of enzyme electrode were tested under flow conditions and the reproducibility and stability of the biosensors were evaluated. The biosensors were used for fermentation monitoring of glucose in grape must and interference studies were also performed.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6THP-4M0BH9Y-2/1/306f5db86217ea276bf808fb05c02886en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectFlow cellen_US
dc.subjectElectrochemical enzyme biosensoren_US
dc.subjectEnzyme immobilisationen_US
dc.subjectSol-gelen_US
dc.subjectGlucose determinationen_US
dc.subjectGrape musten_US
dc.titleDesign and application of a flow cell for carbon-film based electrochemical enzyme biosensorsen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.talanta.2006.08.032-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypearticle-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.author.orcid0000-0002-8492-5558-
crisitem.author.orcid0000-0002-1972-4434-
Appears in Collections:FCTUC Química - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file751f479d18694aad93df1161e652ae80.pdf469.5 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

27
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations

28
checked on Feb 2, 2024

Page view(s) 50

387
checked on Apr 23, 2024

Download(s)

289
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.