Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4552
DC FieldValueLanguage
dc.contributor.authorVeloso, J. F. C. A.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorConde, C. A. N.-
dc.date.accessioned2008-09-01T11:09:03Z-
dc.date.available2008-09-01T11:09:03Z-
dc.date.issued1999en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 422:1-3 (1999) 273-277en_US
dc.identifier.urihttps://hdl.handle.net/10316/4552-
dc.description.abstractA P10-filled microstrip gas chamber (MSGC) is used to replace the conventional photomultiplier tube (PMT) as the photosensor for a Gas Proportional Scintillation Counter (GPSC). The Vacuum Ultra-Violet (VUV) scintillation light produced in the xenon-filled GPSC is transmitted through a 1 mm thick high-purity quartz window to the MSGC where it is converted to photoelectrons by a CsI photocathode deposited directly onto the surface of a microstrip plate (MSP). These photoelectrons are afterwards multiplied near the microstrip plate anodes with a charge gain of about 103. The energy resolution achieved for 5.9 keV X-rays is 11.5% which, while not yet as good as the 8% figure for standard GPSC (instrumented with a PMT), is already better than the energy resolution obtained for standard proportional counters. Experimental results are presented and discussed. With this design a compact GPSC is obtained which has the further advantage of being much less sensitive to magnetic fields than PMT-based GPSCs.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-3VR1CVW-1Y/1/d58104484bd3814021599b6308e11a80en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectGas proportional scintillation counteren_US
dc.subjectMicrostrip gas chamber photosensoren_US
dc.titlePerformance characteristics of a gas proportional scintillation counter coupled to a microstrip gas chamber photosensoren_US
dc.typearticleen_US
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypearticle-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-7107-7203-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
filea6feed593b4a4baa9b41036802fc6853.pdf251.23 kBAdobe PDFView/Open
Show simple item record

Page view(s) 50

566
checked on Apr 23, 2024

Download(s) 50

677
checked on Apr 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.