Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/38786
DC FieldValueLanguage
dc.contributor.advisorQuintela, Divo Augusto Alegria-
dc.contributor.advisorOliveira, Avelino Virgílio Fernandes Monteiro de-
dc.contributor.authorRodrigues, José Manuel Pires-
dc.date.accessioned2017-03-27T10:53:54Z-
dc.date.available2017-03-27T10:53:54Z-
dc.date.issued2015-09-21-
dc.identifier.urihttps://hdl.handle.net/10316/38786-
dc.descriptionDissertação de Mestrado Integrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractA exposição prolongada a ambientes térmicos quentes pode induzir a alterações fisiológicas sérias no corpo humano, comprometendo muitas vezes o seu sistema termorregulador. Em particular, poderão ser experienciadas situações de stresse térmico responsáveis por originar patologias, ou até mesmo acidentes de trabalho fatais. Para entender quais as razões ou fatores que afetam este problema, é pois relevante ter conhecimento não só do comportamento termofisiológico do ser humano, como também do meio que o rodeia. A fim de estudar esta temática existem vários modelos de cálculo, que fornecem índices de caracterização de ambientes térmicos quentes, entre os quais o modelo Predicted Heat Strain (PHS), que tem como objetivo a determinação analítica e interpretação de situações de stresse térmico. O presente trabalho tem então como objetivo estudar os efeitos da exposição ao calor em ambientes térmicos quentes na indústria cerâmica portuguesa, aplicando o modelo PHS da norma internacional ISO 7933:2004. Para isso, é usado um programa que aplica o algoritmo de cálculo da referida norma, por forma a analisar e comparar os índices térmicos resultantes que auxiliam na caracterização das situações em estudo. Por fim, são apresentados e analisados os resultados gráficos que comprovam um elevado número de trabalhadores em risco de stresse térmico.pt
dc.description.abstractA long exposure to hot thermal environments can lead to serious physiological changes in the human body, compromising its thermoregulatory system. In particular, the human being can experience situations of heat stress, responsible by pathologies, or even deathly accidents. In order to understand the reasons or aspects which can affect this problem, it is important to be aware not only of the human thermoregulatory behavior, but also the environment around it. There are several calculation models to study this issue, which provide us some indexes to characterize hot thermal environments, in particular the Predicted Heat Strain (PHS) model, which goal is to do analytical determination and interpretation of thermal stress situations. The aim of this work is to study the effects of heat exposure in hot thermal environments in the Portuguese ceramic industry, applying the PHS model provided by the international standard ISO 7933:2004. To do this, it is used a software that applies the algorithm calculation of the international standard, in order to analyze and compare the results of the thermal indexes. Finally, the results are represented by graphics, showing a high number of workers in thermal stress. Keywords , Thermal Stress, PHS Model, Thermal Indexes,pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectAmbientes Térmicos Quentespt
dc.subjectStresse Térmicopt
dc.subjectExposição ao calorpt
dc.subjectModelo PHSpt
dc.subjectÍndices Térmicospt
dc.subjectIndústria Cerâmicapt
dc.subjectHot Thermal Environmentspt
dc.subjectThermal Stresspt
dc.subjectPHS Modelpt
dc.subjectThermal Indexespt
dc.subjectCeramic Industrypt
dc.titleCondições de trabalho na indústria cerâmica: avaliação da exposição ao calorpt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2015-09-21*
dc.identifier.tid201661195pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia do Ambientept
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.openairetypemasterThesis-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Files in This Item:
Show simple item record

Page view(s) 50

451
checked on Jul 16, 2024

Download(s) 20

1,280
checked on Jul 16, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.