Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/38773
DC FieldValueLanguage
dc.contributor.advisorGóis, José Carlos Miranda-
dc.contributor.advisorGaspar, Adélio Manuel Rodrigues-
dc.contributor.authorApolinário, João Pedro Félix-
dc.date.accessioned2017-03-27T10:53:52Z-
dc.date.available2017-03-27T10:53:52Z-
dc.date.issued2015-09-17-
dc.identifier.urihttps://hdl.handle.net/10316/38773-
dc.descriptionDissertação de Mestrado Integrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractOs complexos desportivos, em especial os que possuem piscinas interiores, devem proporcionar aos utentes boa qualidade do ar, da água e conforto térmico no espaço envolvente à piscina, o que faz com que os consumos de energia térmica e elétrica sejam bastante elevados. Importa por isso analisá-los e tentar maximizar a sua eficiência energética, de forma a contribuir para a redução das despesas dos municípios com estes edifícios. Esta dissertação tem como caso de estudo o Complexo de Piscinas Rui Abreu, situado em Coimbra. São analisados consumos e respetivos custos de eletricidade, gás natural e água. Diversos indicadores relativos ao consumo e custo de energia e de água, por número de utentes, área de superfície de piscina e área útil de edifício, são calculados e comparados com valores de estudos similares. Para os indicadores de energia por área de superfície de piscina obteve-se 726 kWh/m2.ano em eletricidade e 1415 kWh/m2.ano em gás natural, totalizando 2141 kWh/m2.ano de energia total. Estes e outros indicadores mostraram ser da mesma ordem de grandeza de indicadores obtidos em outros complexos com piscinas interiores. Em termos de energia primária, o complexo consome 60,6 kgep/ m2.ano. Através de uma desagregação simplificada do consumo de energia térmica, concluiu-se que 71 % do consumo de gás natural é referente ao aquecimento da água das piscinas e 14 % ao aquecimento de AQS. A energia térmica consumida no aquecimento do edifício deverá rondar os 15%. As elevadas necessidades térmicas e elétricas que o edifício demonstrou abrem a oportunidade de estudar a implementação de um sistema de cogeração. No entanto, o payback encontrado para as diferentes soluções de cogeração tornam o projeto pouco viável em termos económicos. Palavras-chave: , ,pt
dc.description.abstractSport complexes, especially those that have indoor swimming pools, must provide comfort conditions to their users, regarding air and water quality and thermal comfort. In order to offer a suitable comfort, a high energy consumption is required, both electrical and thermal. Since the energy consumption is so high, it is essential to analyze the energy consumption and cost, in order to optimize the energy efficiency and support City Hall to reduce the costs related to energy. This thesis has as case study the Rui Abreu Swimming Pool Complex, located in Coimbra, Portugal. The consumption of electricity, natural gas and water and respective costs are analyzed, and energy efficiency indicators are obtained. Using the area of the swimming pool as reference, it was obtained 726 kWh/m2.year of electricity, 1415 kWh/m2.year of natural gas and 2141 kWh/m2.year of total energy. These results are close to other complexes with indoor swimming pools. The consumption in terms of primary energy is 60,6 kgoe/m2.year. The heating of pool water represents 59 % of the natural gas consumption, and the domestic hot water represents 14 %. Thermal energy related to air heating, was not estimated, but should represent about 27 % of that consumption. The high consumption of thermal and electrical energy of the building complex give the opportunity to study the implementation of a CHP (combined heat and power) system. However, the calculated payback period obtained for the different cogeneration solutions is too high for the project to be considered economically feasible.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectEficiência energéticapt
dc.subjectAuditoria Energéticapt
dc.subjectPiscina Cobertapt
dc.subjectConsumo de energiapt
dc.subjectCusto de Energiapt
dc.subjectDesagregação de Consumospt
dc.subjectEnergy Efficiencypt
dc.subjectEnergy Auditpt
dc.subjectEnergy Consumptionpt
dc.subjectEnergy Costspt
dc.subjectConsumption Breakdownpt
dc.titleEficiência energética em complexos de piscinas interiores: complexo de piscinas Rui Abreupt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2015-09-17*
dc.identifier.tid201661071pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia do Ambientept
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
crisitem.advisor.researchunitLAETA - Associated Laboratory for Energy, Transports and Aeronautics-
crisitem.advisor.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.advisor.orcid0000-0002-7087-8041-
crisitem.advisor.orcid0000-0001-6947-4579-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Show simple item record

Page view(s) 50

586
checked on Apr 9, 2024

Download(s) 20

1,291
checked on Apr 9, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.