Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/38751
DC FieldValueLanguage
dc.contributor.advisorGaspar, Adélio Manuel Rodrigues-
dc.contributor.advisorGóis, José Carlos Miranda-
dc.contributor.authorQuintas, Hugo Diogo dos Santos-
dc.date.accessioned2017-03-27T10:53:50Z-
dc.date.available2017-03-27T10:53:50Z-
dc.date.issued2014-09-15-
dc.identifier.urihttps://hdl.handle.net/10316/38751-
dc.descriptionDissertação de Mestrado Integrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractCom a crescente necessidade de recursos energéticos, é imperativo fazer uma gestão mais racional. Neste contexto, este trabalho centra-se no estudo de alternativas tecnológicas que apresentem maior eficiência do que as convencionais, tendo como caso de estudo o conjunto do complexo olímpico de piscinas de Coimbra e o centro comercial Dolce Vita de Coimbra, por forma a proporcionar uma maior saúde financeira e ambiental. É realizada uma interpretação dos consumos e custos da energia elétrica e térmica dos dois edifícios. Com esta análise a perceção das necessidades energéticas dos dois estabelecimentos ficou clara e assim foram considerados para análise energética três tipos de tecnologia que mais se adequam ao local e às necessidades conjuntas: sistema de cogeração/trigeração, coletores solares e painéis fotovoltaicos. Para o sistema cogeração/trigeração, não foi possível retirar conclusões, sendo apenas feito um enquadramento teórico e calculados os perfis de utilização. Em relação aos coletores solares e painéis fotovoltaicos, foram feitas as devidas simulações na sua aplicação ao complexo olímpico de piscinas de Coimbra, que permitem retirar as seguintes conclusões: (1) o investimento nos sistemas solares térmicos e fotovoltaicos é bastante elevado, (2) mesmo assim os dois sistemas apresentam lucro económico no final do tempo de vida (20 anos), (3) em termos energéticos, económicos e ambientais, os resultados são de um modo geral positivos nos cenários considerados.pt
dc.description.abstractWith the growing need for energy resources, it is imperative to make a more rational management. In this context, this paper focuses on the study of technological alternatives that have higher efficiency than the conventional, taking as a case study the Olympic pool complex of Coimbra and Dolce Vita Coimbra shopping center in order to provide a greater financial and environmental health. An interpretation of the consumption and cost of electricity and thermal energy of the two buildings was made. With this analysis the perception of the energy requirements of the two establishments was clear and so was considered for energy analysis three types of technology that best suit the local and combined needs: cogeneration/trigeneration, solar collectors and photovoltaic system. For cogeneration/trigeneration system, it was not possible to draw conclusions, being only a theoretical framework and calculated profiles of use. Regarding solar collectors and photovoltaic panels, appropriate simulations were made in its application to the Olympic pool complex of Coimbra, which allow the following conclusions: (1) investment in solar thermal and photovoltaic systems is quite high, (2) still the two systems present economic profit at the end of the lifetime (20 years), (3) in terms of energy, economic and environmental, the results are relatively positive in the scenarios considered.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectPiscinas interiorespt
dc.subjectEdifícios comerciaispt
dc.subjectCogeraçãopt
dc.subjectTrigeraçãopt
dc.subjectColetores solarespt
dc.subjectPainéis fotovoltaicospt
dc.subjectIndoor poolspt
dc.subjectCommercial buildingspt
dc.subjectCogenerationpt
dc.subjectTrigenerationpt
dc.subjectSolar collectorspt
dc.subjectPhotovoltaic panelspt
dc.titleAnálise de soluções de produção de energia em complexos desportivos: Casa do Complexo Olímpico de Piscinas de Coimbrapt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2014-09-15*
dc.identifier.tid201660873pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia do Ambientept
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypemasterThesis-
item.languageiso639-1pt-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.advisor.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.advisor.researchunitLAETA - Associated Laboratory for Energy, Transports and Aeronautics-
crisitem.advisor.orcid0000-0001-6947-4579-
crisitem.advisor.orcid0000-0002-7087-8041-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Files in This Item:
File Description SizeFormat
Dissertação - Hugo Quintas.pdf9.6 MBAdobe PDFView/Open
Show simple item record

Page view(s) 10

1,027
checked on Apr 23, 2024

Download(s)

85
checked on Apr 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.