dc.description.abstractSendo a indústria transformadora como das mais delicadas a nível de postos de trabalho em ambientes térmicos quentes, é necessária uma avaliação correta e precisa da ocorrência de stresse térmico entre os trabalhadores com vista à prevenção de acidentes de trabalho e, consequentemente, o aumento da produtividade. A indústria vidreira é, no campo da exposição ao calor, das mais problemáticas e o método para realizar esta avaliação passa pela realização de um conjunto de medições nos postos de trabalho mais críticos. Para tal, este estudo é apoiado num conjunto de ferramentas que passam pela aplicação de normas internacionais, nomeadamente a norma ISO 7243:1989 e a norma 7933:2004. A norma ISO 7243:1989 tem como base o índice WBGT (Wet Bulb Globe Temperature), enquanto a norma ISO 7933:2004 apoia-se no modelo PHS (Predicted Heat Strain). Para aplicação do modelo PHS, devido à sua complexidade de cálculo, recorreu-se a um programa em linguagem matlab que aplica o algoritmo de cálculo da norma. Com vista a uma realista e alargada avaliação dos resultados, foram compiladas o maior número de medições possíveis, reunidas de contribuições de trabalhos de investigação anteriormente desenvolvidos na área da indústria vidreira. Foi, ainda, avaliado o stresse térmico presente nos postos de trabalho e foi estudada a influência de vários parâmetros nas variáveis físicas de saída do modelo PHS. No total, foram avaliados os ambientes térmicos de 19 postos de trabalho provenientes de 5 indústrias vidreiras localizadas na zona centro de Portugal, resultado de medições realizadas ao longo dos últimos 22 anos. Conclui-se, no geral, que grande parte dos postos analisados estão em risco de stresse térmico e que este pode ser diminuído ou mesmo anulado com a alteração de alguns parâmetros físicos.por
dc.description.abstractAs manufacturing is one of the most sensitive in terms of jobs in hot thermal environments a proper and accurate assessment of the occurrence of heat stress of workers is necessary in order to prevent accidents and therefore increase productivity. The glass industry is the most problematic in the matter of heat exposure and the method to carry out this evaluation involves the realization of a set of measurements of the most critical workplaces. To that end, this study is supported by a set of tools that undergo the application of international standards, including ISO 7243:1989 and standard 7933:2004. The ISO 7243:1989 norm is based on the WBGT index (Wet Bulb Globe Temperature), while the ISO 7933:2004 norm is supported by the PHS model (Predicted Heat Strain). For the application of the PHS model due to its complex calculation, it was used a matlab language program that applies the standard calculation algorithm With a view to a realistic and comprehensive evaluation of the results, the largest possible number of measurements were compiled, which were gathered from contributions from previous research in glass industry. Furthermore, the thermal stress in the workplaces was evaluated and the influence of various parameters on physical variables output from the PHS model was also studied. In total, the thermal environments of 19 workplaces of 5 glass industries located in central Portugal where evaluated. This was the result of measurements made over the past 22 years. It was concluded, in general, that the majority of the analyzed work places are at risk of heat stress and that this can be decreased or even eliminated with the change of some physical parameters.por
dc.language.isoporpor
dc.rightsopenAccesspor
dc.subjectIndustria vidreirapor
dc.subjectAmbientes térmicos quentespor
dc.subjectStress térmicopor
dc.titleCondições de trabalho na indústria vidreira: avaliação da exposição ao calorpor
dc.typemasterThesispor
dc.peerreviewednopor
dc.subject.fosDomínio/Área Científica::Engenharia e Tecnologia::Engenharia Mecânicapor
thesis.degree.grantor00500::Universidade de Coimbrapor
thesis.degree.nameMestrado em Engenharia Mecânica (Produção e Projeto)-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
File Description SizeFormat
Telmo_Fernandes_2004117054_2016_rf.pdf.pdf2.68 MBAdobe PDFView/Open
Show simple item record

Page view(s) 10

938
checked on Apr 16, 2024

Download(s) 20

1,409
checked on Apr 16, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.