Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/27165
Title: The effectiveness method to predict the behaviour of a desiccant wheel: an attempt of experimental validation
Authors: Ruivo, Celestino R. 
Angrisani, Giovanni 
Keywords: Desiccant wheel; Experimental data; Effectiveness method; Validation; Empirical correction
Issue Date: 2013
Publisher: Elsevier
Citation: RUIVO, Celestino R.; ANGRISANI, Giovanni - The effectiveness method to predict the behaviour of a desiccant wheel: an attempt of experimental validation. "Applied Thermal Engineering". ISSN 1359-4311. (2013)
Serial title, monograph or event: Applied Thermal Engineering
Abstract: The desiccant wheel is a key component in solid-desiccant systems. At present, the analysis of the behaviour of air handling units based on desiccant wheels is a complex task. It is difficult to access a simple model that can represent the behaviour of commercialized desiccant wheels with sufficient accuracy. Experimental data measured in an air handling unit equipped with a desiccant wheel are considered in the present work. The air handling unit belongs to a test facility with a microcogeneration system located at Università degli Studi del Sannio (in Benevento, Southern Italy). Thermal energy from the microcogenerator is used to heat up the regeneration airflow. An attempt of investigating the validity of the simplified effectiveness method in predicting the global behaviour of a desiccant wheel is performed. Two approaches are used with different pair of effectiveness parameters. Only one sensor of temperature and one sensor of relative humidity were used in each measuring section of the air handling unit. This constraint is most crucial at both outlet sections of the desiccant wheel due to the strong dependence of the air state on the angular position. An empirical correction of the measured state of the process air at the outlet of the desiccant wheel is used. The corrected data are used in the investigation of the validity of the effectiveness method by using constant values in a large set of cases where the rotation speed of the desiccant wheels and the fans are kept constant. Important deviations between the predicted and the experimental results were found in a significant number of cases, therefore there is the need of improving the method by taking into account the effect on the effectiveness parameters of varying the inlet states of both airflows.
URI: https://hdl.handle.net/10316/27165
ISSN: 1359-4311
DOI: 10.1016/j.applthermaleng.2013.10.028
Rights: openAccess
Appears in Collections:FCTUC Eng.Mecânica - Artigos em Revistas Internacionais

Files in This Item:
Show full item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.