Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/20143
DC FieldValueLanguage
dc.contributor.advisorQuintela, Divo Augusto Alegria-
dc.contributor.authorMatias, Nuno Alexandre de Almeida Nunes-
dc.date.accessioned2012-06-08T01:34:52Z-
dc.date.available2012-06-08T01:34:52Z-
dc.date.issued2011-09-
dc.identifier.citationMATIAS, Nuno Alexandre de Almeida Nunes, - Condições Ambientais de Piscinas Interiores. Coimbra: [s.n], 2011. Dissertação de Mestradopor
dc.identifier.urihttps://hdl.handle.net/10316/20143-
dc.descriptionDissertação de Mestrado em Engenharia Mecânica (Energia e Ambiente), apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbrapor
dc.description.abstractHoje em dia, constata-se uma procura cada vez mais alargada de utilização de piscinas interiores para actividades desportivas, recreativas e terapêuticas. Este tipo de solicitação é uma marca de desenvolvimento e de qualidade de vida da nossa sociedade. Pretende-se, deste modo, que seja uma oferta de qualidade, de forma a que os seus utilizadores retirem o máximo de benefícios, sem que seja posta em causa a sua saúde. Para a obtenção de condições óptimas, tanto a nível da água de piscinas, como da qualidade do ar ambiente interior, é necessário efectuar manutenções periódicas dos sistemas de tratamento da água e de ventilação. É uma tentativa válida para que, a médio prazo, possam vir a melhorar as condições de conforto e de higiene tanto para os utentes, como para os trabalhadores. Com este trabalho, pretende-se efectuar amostragens de natureza Química e Microbiológica relacionadas com a Qualidade do Ar, tendo em vista não só a detecção da presença de Trihalometanos, com base nos limites impostos pela Organização Mundial de Saúde (OMS), recorrendo a um aparelho Personal Air Sampling Pump, mas também de Bactérias e Fungos recorrendo ao equipamento SAS Super IAQ. No que concerne à temática do Conforto Térmico, determinar os parâmetros ambientais (humidade relativa do ar, temperatura do ar, velocidade do ar e temperatura operativa) e os índices PMV, (Voto Médio Previsto), e PPD, (Percentagem de Pessoas Insatisfeitas), recorrendo ao equipamento Analisador de Climas Interiores Tipo 1213. Posteriormente, em função dos resultados obtidos nas actividades experimentais, pretende-se compará-los com os que se encontram estipulados em Normas e em Decretos-Lei para averiguar se os espaços, objecto de estudo, apresentam condições adequadas de conforto e higiene.por
dc.description.abstractThese days there is an ever increasing demand for the use of internal pools for sporting, recreational and therapeutic activities. This type of demand is a mark of progress and the standard of living within our current society. It is the intention, therefore, to provide a quality solution in order to ensure that swimmers can obtain the maximum of benefit, without there being a risk to their health or safety. To ensure these optimal conditions, one must consider the routine or periodical maintenance of water treatment and ventilation in order to maintain the water level of the pool and the air quality within the installations. It is a worthy and valid effort in order to, in the medium term; create improvements to the level of comfort and hygiene for users of the pool and for the employees of the installations. The intention of this study is to carry out a sampling of the Chemical and Microbiological nature within the Air Quality, taking into account not only the detection of the presence of Trihalomethanes, based upon the limits stipulated by the World Health Organization (WHO), using a Personal Air Sampling Pump, but also Bacteria and Fungi utilizing a SAS Super IAQ. With regards to the theme of Thermal Comfort, determining environmental parameters (relative air moisture, air temperature, air speed and operating temperatures) and the PMV (Predicted Mean Vote) rates, and PPD (Predicted Percentage of Dissatisfied), by using an Indoor Climate Analyzer Type 1213. After which, according to the results obtained during the sampling experiments, the intention is to then compare these to what is stipulated within legislative standards to ascertain as to whether these spaces, the object of this study, present adequate conditions of comfort and hygiene.por
dc.language.isoporpor
dc.rightsopenAccesspor
dc.subjectQualidade do Arpor
dc.subjectPiscinas Interiorespor
dc.subjectInternal Pools-
dc.subjectThermal Comfort-
dc.subjectAir Quality-
dc.subjectTrihalomethanes-
dc.subjectTrihalometanos-
dc.titleCondições Ambientais de Piscinas Interiorespor
dc.typemasterThesispor
degois.publication.locationCoimbrapor
degois.publication.titleCondições Ambientais de Piscinas Intreriorespor
dc.peerreviewedNopor
item.openairetypemasterThesis-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
File Description SizeFormat
Condições Ambientais de Piscinas Interiores.pdf2.56 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

551
checked on Jul 16, 2024

Download(s) 10

2,478
checked on Jul 16, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.