Title: Aspectos do Comportamento Higrotérmico de um Edifício de Elevada Inércia Térmica. Caso de uma Biblioteca do Séc. XVIII
Authors: Gaspar, A. 
Quintela, D. A. 
Figueiredo, A. R. 
Keywords: Thermal performance of buildings; Cooling; Dehumidification loads
Issue Date: 1994
Publisher: Asociación Española de Energía Solar
Citation: GASPAR, A.; QUINTELA, D. A.; FIGUEIREDO, A. R. - Aspectos do Comportamento Higrotérmico de um Edifício de Elevada Inércia Térmica. Caso de uma Biblioteca do Séc. XVIII. In VÁZQUEZ VÁZQUEZ, Manuel; MORÁN GONZÁLEZ, Jorge Carlos, ed. lit. - Energías límpias en progreso : libro de actas del VII Congreso Ibérico de Energía Solar. Vigo : Asociación Española de Energía Solar, 1994. Vol. 1, p. 657-662
Serial title, monograph or event: Energías límpias en progreso : libro de actas del VII Congreso Ibérico de Energía Solar
Volume: 1
Place of publication or event: Vigo
Abstract: Neste trabalho analisa-se, de forma preliminar, o comportamento higrotérmico de uma biblioteca construída no século XVIII, pertencente ao núcleo histórico-arquitectónico da Universidade de Coimbra, a partir de dados registados numa campanha de medidas executadas por termo-higrómetros, durante os meses de Junho e Julho de 1993. Caracteriza-se a envolvente do edifício do ponto de vista da sua inércia térmica e simula-se o comportamento do piso superior, claramente mais sensível às solicitações climáticas exteriores, utilizando um algoritmo de cálculo apropriado. Aproveitando as características de elevada inércia do edifício, procura-se estabelecer as condições higrotérmicas interiores compatíveis com a preservação dos espécimes bibliográficos existentes, recorrendo a potências baixas e reduzidos custos de funcionamento.
A preliminar analysis is presented concerning the hygrothermal behaviour of the XVIII century library of the University of Coimbra, wich is based on temperature and relative hurnidity measurements canied out during June and July 1993. A simulation is made utilysing a suitable algorithm wich takes account of the thermal inertia of the building and the tirne-evolutions of the outdoor values of temperature, relative humidity, global and diffuse solar radiation. It was possible to demonstrate that reasonable leveIs of internal temperature and relative humidity can be obtained with the use of relatively small climatisation plants and corresponding low energy costs.
URI: https://hdl.handle.net/10316/14564
ISBN: 8460500489
Rights: openAccess
Appears in Collections:FCTUC Eng.Mecânica - Artigos e Resumos em Livros de Actas

Files in This Item:
File Description SizeFormat
Aspectos do Comportamento Higrotérmico.pdf1.93 MBAdobe PDFView/Open
Show full item record

Page view(s) 50

440
checked on Apr 16, 2024

Download(s)

198
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.