Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/113792
DC FieldValueLanguage
dc.contributor.authorFerreira, Matheus A. C.-
dc.contributor.authorCarvalho, Dionísio D. A.-
dc.contributor.authorCruz, Agnaldo S.-
dc.contributor.authorCoutinho, Karilany D.-
dc.contributor.authorOliveira, Carlos A. P.-
dc.contributor.authorMorais, Antonio H. F.-
dc.contributor.authorSantos, João Paulo Q.-
dc.contributor.authorMayrink, Nadja N. V.-
dc.contributor.authorGalvão-Lima, Leonardo J.-
dc.contributor.authorSales-Moioli, Ana Isabela L.-
dc.contributor.authorBarros, Daniele M. S.-
dc.contributor.authorAlbuquerque, Gabriela A.-
dc.contributor.authorAlves, Luca P. C. F.-
dc.contributor.authorTeixeira, César A.-
dc.contributor.authorHenriques, Jorge M. O.-
dc.contributor.authorGil, P. Sousa-
dc.contributor.authorGusmão, Cristine M. G.-
dc.contributor.authorValentim, Ricardo A. M.-
dc.date.accessioned2024-03-04T11:52:52Z-
dc.date.available2024-03-04T11:52:52Z-
dc.date.issued2022-
dc.identifier.issn2446-4740pt
dc.identifier.urihttps://hdl.handle.net/10316/113792-
dc.description.abstractPurpose Primary Health Care (PHC) is the coordinator of health care in Brazil and needs to be strengthened in the diagnostic field to increase health care quality. Aiming to improve the diagnostic tools currently available in PHC, this work describes the process of development and validation of two point-of-care biomedical devices for screening patients with syphilis or different kinds of cancer. Methods The development of these devices followed nine stages of action based on the requirements established by the Ministry of Health. During development, both systems followed the stages of circuit planning, software simulation to verify the components used, cost assessment for the acquisition of features, simulation in contact matrix, development of the embedded system, and planning of the printed circuit board and storage box. Results Both devices underwent preliminary functionality tests to assess their quality. The performance tests applied on the device to diagnose syphilis performed 8,733,194 requests, with a flow of 2426 requests/second, reaching the desired parameters of robustness, integrity, durability, and stability. In addition, functioning tests on the cancer-screening device indicated the ability to detect standard fluorescence in a minimal (150 uL) sample volume. Conclusions Together, the methodology used for developing the devices resulted in promising equipment to improve the diagnosis and meet the requirements for executing technologies for testing and triaging patients in PHC.pt
dc.language.isoengpt
dc.publisherSociedade Brasileira de Engenharia Biomedicapt
dc.relation“Syphilis No!” Project from the Brazilian Ministry of Health (Grant TED No #54/2017)pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjectEmbedded systempt
dc.subjectPrimary health carept
dc.subjectBiosensorspt
dc.subjectSyphilispt
dc.subjectCancerpt
dc.titleDevelopment of technologies to support the diagnosis of infectious diseases and cancer to support the primary health carept
dc.typearticle-
degois.publication.firstPage27pt
degois.publication.lastPage35pt
degois.publication.issue1pt
degois.publication.titleResearch on Biomedical Engineeringpt
dc.peerreviewedyespt
dc.identifier.doi10.1007/s42600-022-00247-7pt
degois.publication.volume39pt
dc.date.embargo2022-01-01*
uc.date.periodoEmbargo0pt
item.fulltextCom Texto completo-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
crisitem.author.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.author.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.author.parentresearchunitFaculty of Sciences and Technology-
crisitem.author.parentresearchunitFaculty of Sciences and Technology-
crisitem.author.orcid0000-0001-9396-1211-
crisitem.author.orcid0000-0003-0937-4044-
Appears in Collections:FCTUC Eng.Informática - Artigos em Revistas Internacionais
I&D CISUC - Artigos em Revistas Internacionais
Show simple item record

Page view(s)

74
checked on Oct 16, 2024

Download(s)

17
checked on Oct 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons