Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/108118
DC FieldValueLanguage
dc.contributor.authorRoque, Eduardo-
dc.contributor.authorSantos, Paulo-
dc.date.accessioned2023-08-11T16:26:41Z-
dc.date.available2023-08-11T16:26:41Z-
dc.date.issued2017-
dc.identifier.issn2075-5309-
dc.identifier.urihttps://hdl.handle.net/10316/108118-
dc.description.abstractLightweight steel-framed (LSF) construction, given its advantages, has the potential to reach high standards in energy and environmental performance of buildings, such as nearly zero-energy buildings (nZEB). When compared with traditional construction, LSF system offers distinct benefits in such fields as sustainability, cost-effectiveness, constructive process, and safety at work. Despite the benefits of this constructive system, the effect of thermal bridges in LSF elements, caused by the high thermal conductivity of the steel structure, can be a disadvantage. The excessive heat losses or gains through these thermal bridges are more relevant in buildings’ exterior envelope, such as facade walls. These building components’ thermal performance is crucial in the buildings’ overall energetic behaviour, with a direct impact on energy consumption and resulting monetary costs during their operational stage. In this work the influence of the thermal insulation position on its effectiveness is evaluated in LSF facade walls. For this purpose, several LSF wall types are assessed, namely cold, warm, and hybrid construction. The influence of thermal bridges instigated by the steel studs in the LSF walls’ overall thermal performance is evaluated as well. The computations are performed using specialized finite element software (THERM).pt
dc.language.isoengpt
dc.publisherMDPIpt
dc.relationPOCI-01-0145-FEDER-007633pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjectlightweight steel-framedpt
dc.subjectLSFpt
dc.subjectthermal performancept
dc.subjectthermal bridgespt
dc.subjectinsulation effectivenesspt
dc.subjectenergy efficiencypt
dc.titleThe Effectiveness of Thermal Insulation in Lightweight Steel-Framed Walls with Respect to Its Positionpt
dc.typearticlept
degois.publication.firstPage13pt
degois.publication.issue1pt
degois.publication.titleBuildingspt
dc.peerreviewedyespt
dc.identifier.doi10.3390/buildings7010013-
degois.publication.volume7pt
dc.date.embargo2017-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
crisitem.author.researchunitISISE - Institute for Sustainability and Innovation in Structural Engineering-
crisitem.author.orcid0000-0002-0134-6762-
Appears in Collections:I&D ISISE - Artigos em Revistas Internacionais
Show simple item record

Page view(s)

64
checked on May 8, 2024

Download(s)

42
checked on May 8, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons