Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/107716
DC FieldValueLanguage
dc.contributor.authorSilva, Susana Figueiredo-
dc.contributor.authorDomingues, José Paulo-
dc.contributor.authorMorgado, António Miguel-
dc.date.accessioned2023-07-28T10:11:38Z-
dc.date.available2023-07-28T10:11:38Z-
dc.date.issued2018-
dc.identifier.issn2040-2295pt
dc.identifier.urihttps://hdl.handle.net/10316/107716-
dc.description.abstractTime-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.pt
dc.language.isoporpt
dc.publisherHindawipt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subject.meshAlgorithmspt
dc.subject.meshHeLa Cellspt
dc.subject.meshHumanspt
dc.subject.meshImage Processing, Computer-Assistedpt
dc.subject.meshMicroscopy, Fluorescencept
dc.titleAccurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioningpt
dc.typearticle-
degois.publication.firstPage1371386pt
degois.publication.lastPage7pt
degois.publication.titleJournal of Healthcare Engineeringpt
dc.peerreviewedyespt
dc.identifier.doi10.1155/2018/1371386pt
degois.publication.volume2018pt
dc.date.embargo2018-01-01*
uc.date.periodoEmbargo0pt
item.languageiso639-1pt-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
crisitem.author.orcid0000-0002-3565-3162-
crisitem.author.orcid0000-0001-9455-1206-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
FMUC Medicina - Artigos em Revistas Internacionais
I&D IBILI - Artigos em Revistas Internacionais
Show simple item record

Page view(s)

63
checked on Sep 11, 2024

Download(s)

33
checked on Sep 11, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons