Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/107677
DC FieldValueLanguage
dc.contributor.authorAlves, Vítor H. P.-
dc.contributor.authorCarmo, Sérgio do-
dc.contributor.authorAlves, Francisco-
dc.contributor.authorAbrunhosa, Antero-
dc.date.accessioned2023-07-26T11:52:25Z-
dc.date.available2023-07-26T11:52:25Z-
dc.date.issued2018-
dc.identifier.issn2410-390X-
dc.identifier.urihttps://hdl.handle.net/10316/107677-
dc.description.abstractAn automated process for the production and purification of radiometals produced by irradiating liquid targets in a medical cyclotron, using a commercially available module, has been developed. The method is suitable for the production and purification of radiometals such as 68Ga, 64Cu and 61Cu through irradiation of liquid targets and is important for producing high specific activity radioisotopes with a substantial reduction in processing time and cost when compared with the solid target approach. The “liquid target” process also eliminates the need for pre- and post-irradiation target preparation and simplifies the transfer of irradiated material from target to hotcell. A 68GaCl3 solution can be obtained in about 35 min with an average yield of 73.9 6.7% in less than 10 mL of volume. 64CuCl2 solutions can be obtained with an average yield of 81.2 7.8% in about 1 h of processing time. A dedicated single-use disposable kit is used on a commercial IBA Synthera® extension module.pt
dc.language.isoengpt
dc.publisherMDPIpt
dc.rightsopenAccesspt
dc.subjectliquid targetspt
dc.subjectmedical cyclotronpt
dc.subjectradiometalspt
dc.subjectgallium-68pt
dc.subjectcopper-64pt
dc.subjectcopper-61pt
dc.subjectpurificationpt
dc.subjectdisposable kitpt
dc.subjectradiopharmaceuticalspt
dc.titleAutomated Purification of Radiometals Produced by Liquid Targetspt
dc.typearticlept
degois.publication.firstPage17pt
degois.publication.issue3pt
degois.publication.titleInstrumentspt
dc.peerreviewedyespt
dc.identifier.doi10.3390/instruments2030017-
degois.publication.volume2pt
dc.date.embargo2018-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
crisitem.author.researchunitLIP – Laboratory of Instrumentation and Experimental Particle Physics-
crisitem.author.researchunitICNAS - Institute for Nuclear Sciences Applied to Health-
crisitem.author.orcid0000-0003-4631-7268-
crisitem.author.orcid0000-0001-8054-4267-
crisitem.author.orcid0000-0002-4145-854X-
Appears in Collections:I&D ICNAS - Artigos em Revistas Internacionais