Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/102489
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Silva, Joana Sílvia Delgado | - |
dc.contributor.advisor | Gonçalves, Lino Manuel Martins | - |
dc.contributor.author | Lima, Ricardo Soares de Albergaria Gonçalves de | - |
dc.date.accessioned | 2022-09-29T22:04:59Z | - |
dc.date.available | 2022-09-29T22:04:59Z | - |
dc.date.issued | 2022-06-08 | - |
dc.date.submitted | 2022-09-29 | - |
dc.identifier.uri | https://hdl.handle.net/10316/102489 | - |
dc.description | Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina | - |
dc.description.abstract | Introdução: A implantação aórtica transcateter valve-in-valve é hoje universalmente aceite como uma opção terapêutica para as válvulas biológicas cirúrgicas ou transcateter degeneradas. Contudo, um dos maiores desafios técnicos deste procedimento são as aortas horizontalizadas. Neste caso apresentar-se-á uma nova forma de colmatar este problema utilizando-se um simples snare endovascular. Caso clínico: Doente do sexo masculino de 80 anos com dispneia para esforços ligeiros a moderados, enquadrando-se numa classe funcional da NYHA III/VI, com mismatch prótese-paciente e estenose aórtica após substituição valvular aórtica por prótese biológica. Tentativa de implantação aórtica percutânea valve-in-valve sem sucesso devido à horizontalização da aorta ascendente, pelo que se recorreu a um snare para defletir o sistema de entrega da grande curvatura da aorta, obtendo-se boa progressão. Conclusão: A utilização de um snare endovascular como um tensor na implantação aórtica transcateter valve-in-valve é efetivamente uma solução viável para contornar o desafio técnico de uma aorta horizontalizada. Introdução: A implantação aórtica transcateter valve-in-valve é hoje universalmente aceite como uma opção terapêutica para as válvulas biológicas cirúrgicas ou transcateter degeneradas. Contudo, um dos maiores desafios técnicos deste procedimento são as aortas horizontalizadas. Neste caso apresentar-se-á uma nova forma de colmatar este problema utilizando-se um simples snare endovascular. Caso clínico: Doente do sexo masculino de 80 anos com dispneia para esforços ligeiros a moderados, enquadrando-se numa classe funcional da NYHA III/VI, com mismatch prótese-paciente e estenose aórtica após substituição valvular aórtica por prótese biológica. Tentativa de implantação aórtica percutânea valve-in-valve sem sucesso devido à horizontalização da aorta ascendente, pelo que se recorreu a um snare para defletir o sistema de entrega da grande curvatura da aorta, obtendo-se boa progressão. Conclusão: A utilização de um snare endovascular como um tensor na implantação aórtica transcateter valve-in-valve é efetivamente uma solução viável para contornar o desafio técnico de uma aorta horizontalizada. | por |
dc.description.abstract | Introduction: The valve-in-valve transcatheter aortic implantation is today universally accepted as a treatment option for degenerated surgical or transcatheter biologic valves. However, one of the biggest technical challenges of this procedure is horizontalized aortas. In this case, it will be presented a new way of solving this problem using a simple endovascular snare. Key points from the case: 80-year-old male patient with dyspnea for mild to moderate physical activity, NYHA class III/VI, with a prosthesis-patient mismatch and aortic stenosis following a biologic prosthesis aortic valve replacement. Unsuccessful percutaneous valve-in-valve aortic implantation due to the ascending aorta horizontalization. A snare was used to deflect the delivery system from the greater curvature of the aorta, with good advancement. Conclusion: The use of an endovascular snare as a tensioner in valve-in-valve transcatheter aortic implantation is indeed a viable solution to overcome the technical challenge of a horizontalized aorta.Introduction: The valve-in-valve transcatheter aortic implantation is today universally accepted as a treatment option for degenerated surgical or transcatheter biologic valves. However, one of the biggest technical challenges of this procedure is horizontalized aortas. In this case, it will be presented a new way of solving this problem using a simple endovascular snare. Key points from the case: 80-year-old male patient with dyspnea for mild to moderate physical activity, NYHA class III/VI, with a prosthesis-patient mismatch and aortic stenosis following a biologic prosthesis aortic valve replacement. Unsuccessful percutaneous valve-in-valve aortic implantation due to the ascending aorta horizontalization. A snare was used to deflect the delivery system from the greater curvature of the aorta, with good advancement. Conclusion: The use of an endovascular snare as a tensioner in valve-in-valve transcatheter aortic implantation is indeed a viable solution to overcome the technical challenge of a horizontalized aorta. | eng |
dc.language.iso | por | - |
dc.rights | embargoedAccess | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Doença valvular aórtica | por |
dc.subject | Substituição de válvula aórtica transcateter | por |
dc.subject | Bioprótese valvular cardíaca | por |
dc.subject | Snare endovascular | por |
dc.subject | Degeneração de bioprótese | por |
dc.subject | Aortic valve disease | eng |
dc.subject | Transcatheter aortic valve replacement | eng |
dc.subject | Heart valve bioprosthesis | eng |
dc.subject | Endovascular snare | eng |
dc.subject | Bioprosthesis degeneration | eng |
dc.title | Técnica com snare endovascular: uma nova solução na TAVI valve-in-valve em aortas horizontalizadas – um caso clínico | por |
dc.title.alternative | Endovascular snare technique: a new solution for valve-in-valve TAVI in horizontalized aortas - a case report | eng |
dc.type | masterThesis | - |
degois.publication.location | Coimbra | - |
degois.publication.title | Técnica com snare endovascular: uma nova solução na TAVI valve-in-valve em aortas horizontalizadas – um caso clínico | por |
dc.date.embargoEndDate | 2024-06-07 | - |
dc.peerreviewed | yes | - |
dc.date.embargo | 2024-06-07 | * |
dc.identifier.tid | 203067509 | - |
thesis.degree.discipline | Medicina | - |
thesis.degree.grantor | Universidade de Coimbra | - |
thesis.degree.level | 1 | - |
thesis.degree.name | Mestrado Integrado em Medicina | - |
uc.degree.grantorUnit | Faculdade de Medicina | - |
uc.degree.grantorID | 0500 | - |
uc.contributor.author | Lima, Ricardo Soares de Albergaria Gonçalves de::0000-0002-5537-6748 | - |
uc.degree.classification | 16 | - |
uc.date.periodoEmbargo | 730 | - |
uc.degree.presidentejuri | Ferreira, Maria João Soares Vidigal Teixeira | - |
uc.degree.elementojuri | Jorge, Elisabete Sofia Azenha Balhau | - |
uc.degree.elementojuri | Silva, Joana Sílvia Delgado | - |
uc.contributor.advisor | Silva, Joana Sílvia Delgado::0000-0001-7065-9773 | - |
uc.contributor.advisor | Gonçalves, Lino Manuel Martins | - |
item.fulltext | Com Texto completo | - |
item.grantfulltext | open | - |
item.languageiso639-1 | pt | - |
item.cerifentitytype | Publications | - |
item.openairetype | masterThesis | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
Appears in Collections: | UC - Dissertações de Mestrado |
This item is licensed under a Creative Commons License