dc.descriptionDissertação de Mestrado em Engenharia Mecânica, na especialidade de Energia e Ambiente, apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractUma parte significativa dos custos associados ao funcionamento de um edifício de serviços deve-se aos gastos de energia com o AVAC. Assim sendo, a necessidade da sua redução torna-se importante no sentido da poupança de energia e claro está, na poupança monetária. No presente trabalho efetua-se uma análise de consumos energéticos referentes à climatização (aquecimento e arrefecimento) e à ventilação de um edifício de serviços com ocupação intermitente e elevadas cargas térmicas. O edifício estudado foi um supermercado com uma área bruta de pavimento de 1143 m2, classificado com uma inércia fraca segundo a regulamentação nacional. O objetivo passou por avaliar a influência de cada estratégia no consumo energético, preservando as condições de ocupação do edifício, para identificar estratégias mais eficazes na redução dos consumos de energia. O estudo foi efetuado com o auxílio de ferramentas computacionais de simulação dinâmica de edifícios, utilizando o programa EnergyPlus associado à interface gráfica DesignBuilder. Para a execução deste estudo foram considerados sistemas de ventilação mecânicos, naturais e híbridos. Foi ainda estudada a influência da existência ou não de estratégias “economizadoras” como o arrefecimento noturno e a recuperação de calor contido no ar de rejeição. A análise de resultados foi feita com base nas necessidades e nos consumos anuais de energia para a ventilação e para a climatização, nas suas componentes para aquecimento e para arrefecimento.pt
dc.description.abstractA significant portion of the costs associated with the operation of a service building is due to the energy comsuptions from HVAC. Thus, the need of reduction becomes important to saving energy and of course, for monetary savings. This paper, makes an analysis of energy consumption related to HVAC (heating and cooling) and ventilation of a building services with intermittent occupancy and high thermal loads. The building model was a supermarket with a gross floor area of 1143 m2, with an inertia rated poor according to national regulations. The aim is evaluate the influence of each strategy on energy consumption, maintaining the conditions of occupancy of the building in order to identify the most effective strategies for reducing energy consumption. The study was done with the aid of computational tools for dynamic simulation of buildings using the software DesignBuilder. To implement this study were considered mechanical ventilation systems, natural and hybrids. "Saving" strategies were studied such as: free-cooling, and heat recovery. Analysis of results was based on the requirements and annual energy consumption for ventilation and air-conditioning, in its components for heating and cooling.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectVentilaçãopt
dc.subjectArrefecimento noturnopt
dc.subjectEdifícios de serviçospt
dc.subjectSimulação dinâmicapt
dc.subjectConsumos energéticospt
dc.subjectClimatizaçãopt
dc.subjectVentilationpt
dc.subjectfree coolingpt
dc.subjectService Buildingspt
dc.subjectDynamics Simulationpt
dc.subjectEnergy consumptionpt
dc.subjectHVACpt
dc.titleInfluência da estratégia de ventilação no consumo energético dos edifícios de serviços com utilização intermitente e elevadas cargas térmicas internaspt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2013-01-01*
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado em Engenharia Mecânicapt
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
Appears in Collections:FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
File Description SizeFormat
Tese_Valter_Vidigueira_2007107069.pdf1.71 MBAdobe PDFView/Open
Show simple item record

Page view(s)

84
checked on Apr 23, 2024

Download(s)

177
checked on Apr 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.