Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/88879
Title: Advantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysis
Authors: Ventura, Tiago 
Lopes, Maria do Carmo Carrilho Calado Antunes 
Rocha, Humberto 
Ferreira, Brigida da Costa 
Dias, Joana
Keywords: Radiation therapy; Beam angle optimization
Issue Date: 2020
Publisher: Springer
Serial title, monograph or event: IFMBE
Volume: 76
Abstract: Radiation therapy (RT) main purpose is to eliminate, in a controlled way, all tumor cells sparing as much as possible the normal tissues. Intensity-Modulated Radiation Therapy (IMRT) is becoming the standard treatment technique in RT. Beam angle optimization (BAO) has potential to confer more quality to IMRT inverse planning process compared to manual trial and error approaches. In this study, the BAO advantages in head-and-neck patients are highlighted, using a patient specific analysis. Fluence optimization was done with Erasmus-iCycle multicriterial engine and BAO optimization was performed using two different algorithms: a combinatorial iterative algorithm and an algorithm based on a pattern search method. Plan assessment and comparison was performed with the graphical tool SPIDERplan. Among a set of forty studied nasopharynx cancer cases, three patients have been select for the specific analysis presented in this work. BAO presented plan quality improvements when beam angular optimized plans were compared with the equidistant beam angle solution and when plans based on non-coplanar beams geometries were compared with coplanar arrangements. Improvement in plan quality with a reduced number of beams was also achieved, in one case. For all cases, BAO generated plans with higher target coverage and better sparing of the normal tissues.
URI: https://hdl.handle.net/10316/88879
ISBN: 978-3-030-31634-1
DOI: 10.1007/978-3-030-31635-8_153
Rights: openAccess
Appears in Collections:I&D CeBER - Livros e Capítulos de Livros

Files in This Item:
File Description SizeFormat
MEDICON2019_paper_58.pdfAdvantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysis716.87 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

2
checked on Apr 1, 2024

WEB OF SCIENCETM
Citations 20

2
checked on Apr 2, 2024

Page view(s)

315
checked on Apr 16, 2024

Download(s)

373
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.