Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/87824
DC FieldValueLanguage
dc.contributor.advisorCaramelo, Francisco José Santiago Fernandes Amado-
dc.contributor.advisorBranco, Miguel Sá Sousa Castelo-
dc.contributor.authorAgostinho, Daniel Andrade Pinho-
dc.date.accessioned2019-11-18T23:17:21Z-
dc.date.available2019-11-18T23:17:21Z-
dc.date.issued2019-09-27-
dc.date.submitted2019-11-18-
dc.identifier.urihttps://hdl.handle.net/10316/87824-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Biomédica apresentada à Faculdade de Ciências e Tecnologia-
dc.description.abstractA doença de Alzheimer (DA) é a mais comum forma de demência humana e, de momento, não possui um critério de diagnóstico bem definido, embora, neste contexto, se dê ênfase ao uso de biomarcadores, provenientes de neuroimagens. Técnicas de imagem como a ressonância magnética (RM), tomografia de emissão de positrões e imagem de tensor de difusão são usadas, quer separadamente, quer numa abordagem multimodal, no estudo e na classificação da DA. As abordagens multimodais concentram-se maioritariamente no uso de biomarcadores baseados na ressonância magnética, que são posteriormente combinados com outro tipo de neuroimagem ou dados biológicos.Nesta tese, propomos analisar os efeitos da combinação dos dados provenientes das 3 modalidades de imagem, bem como estudar a informação complementar que é dada através da combinação de cada modalidade. Para alcançar este objetivo começámos por criar classificadores base, um para cada modalidade de imagem, e depois examinamos os efeitos da sua combinação, usando técnicas de ensemble.Os resultados obtidos mostram que a combinação das 3 modalidades de imagem melhora a performance geral dos classificadores base (exatidão-98%, sensibilidade-99%, especificidade-97%), mas não apresentam uma melhoria significativa em relação ao uso da combinação de apenas MRI+PIB (precisão-98%, sensitividade-99%, especificidade -98%) ou MRI+DTI (precisão-97%, sensitividade-94%, especificidade-99%). Mais ainda, a combinação de PIB+DTI (precisão-91%, sensitividade-93%, especificidade-90%) não mostrou qualquer melhoria em relação aos classificadores base, o que sugere uma falta de informação complementar entre estas duas modalidades de imagem.Estas descobertas podem representar benefícios clínicos não apenas para as instituições, reduzindo custos, mas também para o bem-estar do paciente, reduzindo o desconforto causado pelo longo tempo de aquisição de imagens PET e removendo a necessidade de exposição a radiação ionizante.por
dc.description.abstractAlzheimer’s disease (AD) is the most common form of dementia in humans and currently it does not have a defined diagnostic criterion, although, nowadays, it emphasizes the use of neuroimaging biomarkers. Magnetic resonance imaging (MRI), positron emission tomography (PET) and diffusion tensor imaging (DTI) are used, either alone or in multimodal approaches, in the study and classification of AD. Today’s multimodal approaches focus on the use of MRI related biomarkers, as a base, and then combining them with other type of imaging or biological data.Here we propose to analyse the effects of the combination of the data from the three imaging modalities, as well as study the complementary information, provided from the combination of each modality. To achieve this goal, we start by creating base classifiers, one for each different imaging modality, and then examine the combination effects, using ensemble techniques.The results show that the combination of all three imaging modalities improves the general performance of the base classifiers (accuracy-98%, sensitivity-99%, specificity-97%), however, it did not show a significant improvement over the use of the combination of just MRI+PIB (accuracy-98%, sensitivity-99%, specificity-98%) or MRI+DTI (accuracy-97%, sensitivity-94%, specificity-99%). Furthermore, the combination of PIB+DTI (accuracy-91%, sensitivity-93%, specificity-90%) did not show any improvement over the base classifiers, suggesting a lack of complementary information between the two imaging modalities.These findings could represent clinical benefits not only for the institutions, by reducing costs, but also for the patient’s wellbeing by reducing the discomfort caused by the lengthy acquisition time of the PET scans and by removing the need of exposure to ionizing radiation.eng
dc.description.sponsorshipOutro - This work was supported by Grants Funded by Fundação para a Ciência e 563 Tecnologia, PAC –286 MEDPERSYST, POCI-01-0145-FEDER-016428, 564 BIGDATIMAGE, CENTRO-01-0145-FEDER-000016 financed by Centro 2020 565 FEDER, COMPETE, FCT UID/4539/2013 – COMPETE, POCI-01-0145-FEDER- 566 007440-
dc.language.isoeng-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectDoença de Alzheimerpor
dc.subjectAbordagem Multimodalpor
dc.subjectMachine Learningpor
dc.subjectClassificaçãopor
dc.subjectEnsemble Learningpor
dc.subjectAlzheimer's Diseaseeng
dc.subjectMultimodal Approacheng
dc.subjectMachine Learningeng
dc.subjectClassificationeng
dc.subjectEnsemble Learningeng
dc.titleDiferential diagnosis of alzheimer's disease based on multimodal imaging data (MRI, PIB and DTI)eng
dc.title.alternativeDiagnóstico diferencial da doença de Alzheimer com base em dados de imagem multimodal (MRI, PIB e DTI)por
dc.typemasterThesis-
degois.publication.locationLBIM-FMUC; ICNAS-
degois.publication.titleDiferential diagnosis of alzheimer's disease based on multimodal imaging data (MRI, PIB and DTI)eng
dc.peerreviewedyes-
dc.identifier.tid202308707-
thesis.degree.disciplineEngenharia Biomédica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Biomédica-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Física-
uc.degree.grantorID0500-
uc.contributor.authorAgostinho, Daniel Andrade Pinho::0000-0003-1503-2948-
uc.degree.classification19-
uc.degree.presidentejuriArrais, Joel Perdiz-
uc.degree.elementojuriCaramelo, Francisco José Santiago Fernandes Amado-
uc.degree.elementojuriDuarte, João Valente-
uc.contributor.advisorCaramelo, Francisco José Santiago Fernandes Amado-
uc.contributor.advisorBranco, Miguel Sá Sousa Castelo-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.advisor.researchunitICBR Coimbra Institute for Clinical and Biomedical Research-
crisitem.advisor.researchunitCIBIT - Coimbra Institute for Biomedical Imaging and Translational Research-
crisitem.advisor.parentresearchunitFaculty of Medicine-
crisitem.advisor.orcid0000-0002-0015-8604-
crisitem.advisor.orcid0000-0003-4364-6373-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Tese Daniel Agostinho.pdf7.76 MBAdobe PDFView/Open
Show simple item record

Page view(s)

290
checked on Apr 23, 2024

Download(s)

461
checked on Apr 23, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons