Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/87795
DC FieldValueLanguage
dc.contributor.authorPereira, Luísa Dias-
dc.contributor.authorGaspar, Adélio Rodrigues-
dc.contributor.authorCosta, José Joaquim da-
dc.contributor.authorPereira, Gilberto G.-
dc.contributor.authorCosta, Antonio-
dc.date.accessioned2019-11-12T09:08:04Z-
dc.date.available2019-11-12T09:08:04Z-
dc.date.issued2018-06-
dc.identifier.isbn978-84-09-01619-8-
dc.identifier.urihttps://hdl.handle.net/10316/87795-
dc.descriptionLibro de Actas: CYTEF 2018 − IX Congreso Ibérico | VII Congreso Iberoamericano de las Ciencias y Técnicas del Fríopt
dc.description.abstractIt is recognized worldwide that indoor air quality (IAQ) conditions in museums influence the preservation of the exhibited items. Recently, international guidelines towards environmental management in the field of conservation have been revised, leading to a different perspective on ‘ideal/fixed’ hygrothermal air conditions, namely EN 15757:2010. Herein, some results of the ongoing study of the IAQ conditions in the Science Museum of the University of Coimbra (UC) are discussed, following a continuous monitoring campaign recently implemented (since January 2017). These data are compared with those of a previous study on the environmental conditions of this museum, a XVI-XVIII century heritage building with no mechanical air conditioning and ventilation (HVAC) system, which was grounded on several non-consecutive monitoring campaigns conducted over more than one-year focused on the hygrothermal air conditions of two exhibition rooms of the Museum. The obtained results reinforce the need for further investigation on the subject. HVAC might be required for proper control of the indoor conditions, e.g., for minimizing the impact of the identified risky conditions.pt
dc.language.isoengpt
dc.publisherInstituto de Ingeniería Energética Universitat Politècnica de València - UPVpt
dc.rightsopenAccesspt
dc.subjectMicroclimatept
dc.subjectMuseum conservationpt
dc.subjectHygrothermal analysispt
dc.subjectNatural ventilationpt
dc.subjectHeritage buildingpt
dc.titleIndoor air quality assessment of a naturally ventilated museum in Portugal: evaluation of two halls of permanent exhibitionpt
dc.typearticlept
degois.publication.locationValencia (Spain)pt
degois.publication.titleCYTEF 2018 − IX Congreso Ibérico | VII Congreso Iberoamericano de las Ciencias y Técnicas del Fríopt
dc.peerreviewedyespt
dc.date.embargo2018-06-01*
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.author.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.author.researchunitLAETA - Associated Laboratory for Energy, Transports and Aeronautics-
crisitem.author.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.author.orcid0000-0003-1312-8137-
crisitem.author.orcid0000-0001-6947-4579-
crisitem.author.orcid0000-0002-7015-6989-
crisitem.author.orcid0000-0001-6652-0031-
Appears in Collections:FCTUC Eng.Mecânica - Artigos e Resumos em Livros de Actas
Files in This Item:
File Description SizeFormat
CYTEF2018-IAQ MCUC.pdf9.45 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

558
checked on Apr 16, 2024

Download(s)

125
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.