Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/7772
DC FieldValueLanguage
dc.contributor.authorGhica, Mariana-
dc.contributor.authorBrett, Christopher-
dc.date.accessioned2009-02-17T10:32:56Z-
dc.date.available2009-02-17T10:32:56Z-
dc.date.issued2008en_US
dc.identifier.urihttps://hdl.handle.net/10316/7772-
dc.description.abstractAbstract A biosensor for the determination of heavy metal cations based on glucose oxidase enzymatic inhibition has been developed. The biosensor was assembled on carbon film electrode supports with glucose oxidase immobilised by cross-linking with glutaraldehyde on top of a film of poly(neutral red) as redox mediator, prepared by electropolymerisation. The biosensor was used to determine the metallic cations, cadmium, copper, lead and zinc in the presence of chosen amounts of glucose. The detection limits were found to be 1 µg L-1 for cadmium, 6 µg L-1 for copper, 3 µg L-1 for lead and 9 µg L-1 for zinc. Inhibition constants were determined by using the Dixon plot, and the type of inhibition induced by the metallic cations was evaluated from Cornish-Bowden plots plus Dixon plots, it being found that the inhibition is reversible and competitive for cadmium, mixed for copper and lead and uncompetitive for zinc. Copper-inhibited glucose oxidase to a greater extent followed by cadmium, lead and zinc. Regeneration of the glucose oxidase response was studied by using Ethylene diamine tetracetic acid metal-chelating agent and the nonionic surfactant Triton X-100. The suitability of the biosensor for determination in foodstuffs or beverages which contain trace concentrations of metals was investigated by performing recovery tests in commercial milk samples.en_US
dc.language.isoengeng
dc.rightsopenAccesseng
dc.titleGlucose oxidase inhibition in poly(neutral red) mediated enzyme biosensors for heavy metal determinationen_US
dc.typearticleen_US
dc.identifier.doi10.1007/s00604-008-0018-1en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.author.orcid0000-0002-1590-0816-
crisitem.author.orcid0000-0002-1972-4434-
Appears in Collections:FCTUC Química - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
obra.pdf331.82 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

74
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations 1

70
checked on Apr 2, 2024

Page view(s)

268
checked on Apr 23, 2024

Download(s)

379
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.