Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/7689
DC FieldValueLanguage
dc.contributor.authorCurado Da Silva, R.-
dc.contributor.authorCaroli, E.-
dc.contributor.authorStephen, J.B.-
dc.contributor.authorSiffert, P.-
dc.date.accessioned2009-02-17T10:29:10Z-
dc.date.available2009-02-17T10:29:10Z-
dc.date.issued2003en_US
dc.identifier.citationExperimental Astronomy. 15:1 (2003) 45-65en_US
dc.identifier.urihttps://hdl.handle.net/10316/7689-
dc.description.abstractAbstract The polarisation of astrophysical source emission in the energy range from a few tens of keV up to the MeV region is an almost unexplored field of high-energy astrophysics. Till date, polarimetry in astrophysics–in the energy domain from hard X-rays up to soft ?-rays–has not been pursued due to the difficulties involved in obtaining sufficient sensitivity. Indeed for those few instruments that are capable of performing this type of measurement (e.g. the COMPTEL instrument on the Compton Gamma-ray Observatory and the IBIS instrument on INTEGRAL), polarimetry itself plays a secondary role in the mission objectives, as the efficiencies (0.5% and 10% maximum, respectively) and polarimetric Q factors (0.1 and 0.3, respectively) are relatively limited. In order to perform efficient polarimetric measurements for hard X-ray and soft gamma-ray sources, with an instrument of relatively robust and simple design, a CdTe based telescope (CIPHER: Coded Imager and Polarimeter for High Energy Radiation) is under study. This instrument is based on a thick (10 mm) CdTe position-sensitive spectrometer comprising four modules of 32 32 individual pixels, each with a surface area of 2 2 mm2 (about 160 cm2 total detection area). The polarimetric performance and design optimisation of the CIPHER detection surface have been studied by use of a Monte Carlo code. This detector, due to its intrinsic geometry, can allow efficient polarimetric measurements to be made between 100 keV and 1 MeV. In order to predict the polarimetric performance and to optimise the design and concept of the CIPHER detection plane, a Monte Carlo code based on GEANT4 library modules was developed to simulate the detector behaviour under a polarised photon flux. The Compton double event efficiency, as well bi-dimensional double event distribution maps and the corresponding polarimetric modulation factor will be presented and discussed. Modulation Q factors better than 0.50 and double event total efficiencies greater than 10% were calculated in the energy range between 100 keV and 1 MeV. Herein we will present and discuss the general problems that affect polarimetric measurements in space, such as the inclination of the source with respect to the telescope optical axis and background radiation. Q factor calculations for several beam inclinations as well as for background together with simulated astronomical sources will be presented and discussed.en_US
dc.language.isoengeng
dc.rightsopenAccesseng
dc.titleCipher, A Polarimeter Telescope Concept for Hard X-Ray Astronomyen_US
dc.typearticleen_US
dc.identifier.doi10.1023/B:EXPA.0000028168.26442.30en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
obra.pdf748.97 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

15
checked on Apr 1, 2024

WEB OF SCIENCETM
Citations 10

9
checked on Oct 6, 2020

Page view(s)

222
checked on Apr 9, 2024

Download(s) 20

814
checked on Apr 9, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.